Chapter 4 - 7SR157 · Data Communications Definitions
© 2016 Siemens Protection Devices Limited
Chapter 4 - Page 43 of 58
Binary Output Status Points
Static (Steady-State) Object Number: 10
Change Event Object Number: 11
Control Relay Output Blocks (CROB) Object Number: 12
Binary Output Command Event Object Number: 13
Static Variation reported when variation 0 requested: 1 (Binary Output w/o status)
or 2 (Binary Output with status)
Change Event Variation reported when variation 0 requested: 1 (Binary Output Event w/o Time)
or 2 (Binary Output Event with Time)
Command Event Variation reported when variation 0 requested: 1 (Command Status w/o Time)
or 2 (Command Status with Time)
Point
Index
Description
Default
Change
Event
Assigned
Class
(1, 2, 3
or none)
Default
Variation
Static
Object 10
Default
Variation
Event
Object 11
Default
Command
Event
Object 13
Assigned
Class
(1, 2, 3
or none)
Default
Variation
Command
Event
Object 13
CROB
Supported
Operations
Default
CROB
Operations
89 Service mode
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
90 Local mode
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
91 Local & Remote
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
99 User SP Command 1.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
100 User SP Command 2.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
101 User SP Command 3.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
102 User SP Command 4.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
103 User SP Command 5.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
104 User SP Command 6.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
105 User SP Command 7.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
106 User SP Command 8.
0
2
2
0
1
Pulse On
Latch On
Close
Pulse On
107 User DP Command 1.
0
2
2
0
1
Pulse On
Pulse Off
Latch On
Latch Off
Close
Trip
Pulse On
Pulse Off
108 User DP Command 2.
0
2
2
0
1
Pulse On
Pulse Off
Latch On
Latch Off
Close
Trip
Pulse On
Pulse Off
Содержание 7SR157 Argus
Страница 1: ...Energy Management 7SR157 Argus Check and System Synchronising Relay Reyrolle Protection Devices ...
Страница 2: ......
Страница 4: ...7SR157 Contents ...
Страница 58: ...7SR158 Technical Manual Chapter 3 Page 2 of 18 2022 Siemens Protection Devices Limited ...
Страница 76: ...7SR157 Technical Manual Chapter 4 Page 2 of 58 2016 Siemens Protection Devices Limited ...
Страница 80: ...7SR157 Technical Manual Chapter 4 Page 6 of 58 2016 Siemens Protection Devices Limited ...
Страница 92: ...7SR157 Technical Manual Chapter 4 Page 18 of 58 2016 Siemens Protection Devices Limited ...
Страница 122: ...7SR157 Technical Manual Chapter 4 Page 48 of 58 2016 Siemens Protection Devices Limited ...
Страница 124: ...7SR157 Technical Manual Chapter 4 Page 50 of 58 2016 Siemens Protection Devices Limited ...