Page 40
SITRANS LG200 – INSTRUCTION MANUAL
7ML19985KA02
Wiring
installed such, that, even in the event of rare incidents, ignition sources due to impact and
friction sparks are excluded.
For applications in explosive atmospheres caused by gases, vapors or mists and where
category 1G apparatus is required, electrostatic charges on the non-metallic parts of the
Probe Model 7ML1302-2 (7
x
5), Model 7ML1302-3 (7
x
7), and Model 7ML1303 (7
x
F) shall be
avoided.
Routine tests
A routine voltage test, in accordance with EN 50020 Clause 10.6, shall be conducted on
each Guided Wave Radar Level Transmitter SITRANS LG200 Model 7ML1300-1xxx1-xCA0
between the output/supply circuits and the base of the unit using a test voltage of
500 V AC during one minute.
For KEMA 07ATEX0076 X:
Special conditions for safe use:
For applications in explosive atmospheres caused by gases, vapors or mists and where
category 1G apparatus is required, electrostatic charges on the non-metallic parts of the
Probe Model 7ML1302-2 (7
x
5), Model 7ML1302-3 (7
x
7), and Model 7ML1303 (7
x
F) shall be
avoided.
For KEMA 07ATEX0077 X:
Installation instructions
• For use in potentially explosive atmospheres of flammable gases, fluids or vapors:
The cable entry devices and the closing elements of unused apertures shall be of a
certified flameproof type, suitable for the conditions of use and correctly installed.
• For use in the presence of combustible dust:
The cable entry devices and the closing elements of unused apertures shall be of a
certified flameproof type, suitable for the conditions of use and correctly installed. The
minimum ingress protection requirement of IP 6
5
according to EN 60529 must be
satisfied.
Special conditions for safe use
For applications in explosive atmospheres caused by gases, vapors or mists and where
category 1G apparatus is required, electrostatic charges on the non-metallic parts of the
Probe Model 7ML1302-2 (7
x
5), Model 7ML1302-3 (7
x
7), and Model 7ML1303 (7
x
F) shall be
avoided.
Содержание 7ML1301-1
Страница 1: ...Instruction Manual February 2009 LG200 sitrans ...
Страница 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Страница 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Страница 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Страница 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...