Page 14
SITRANS LG200 – INSTRUCTION MANUAL
7ML19985KA02
Specificat
ions
Single Rigid Rod
Probe, Sanitary
(7ML1303-1D)
Single Rigid Rod
Probe, PFA faced
flange(7ML1303-1E)
Single Flexible Rod
Probe (7ML1304-1)
Single Flexible Rod Probe
for Bulk Solids (7ML1304-2)
Model reference
number
7xF-E
7xF-F
7x1-x
7x2-x
Recommended
applications:
Applications
demanding sanitary
specifications
Extreme corrosives,
coating/buildup, foam
Coating and buildup,
foam; lengths > 6 m
(20 ft) headroom
Granular bulk solids
applications (powders,
grain, dust) 3000 lb pull
down force
Not
recommended
for:
Low dielectric
media (dK < 10)
1
Low dielectric media
(dK < 10)
1
Low dielectric media
(dK < 4)
Solids with dK < 4
Materials/
wetted parts
316L SS, TFE, 15
μ
-
inch (<0.4
μ
m) R
a
All PFA - wetted
surfaces
316L SS, TFE, O-ring
2
316L SS, TFE, O-ring
2
Optional
AL6XN SS
N/A
N/A
N/A
Process seal
316L SS, TFE, no O-
ring
2
PFA, no O-ring
O-ring
2
Sealant
Rod/tube
diameter
ø 12 mm (0.5”) rod
ø 12 mm (0.5”) rod
ø 16 mm (0.625”)
insulation
ø 5 mm (0.188”) cable ø 6 mm (0.25”) cable
Process
connection
thread
N/A
N/A
2” NPT [(Taper), ANSI/
ASME B1.20.1],
G 2” [(BSPP), EN ISO
228-1]
2” NPT [(Taper), ANSI/
ASME B1.20.1],
G 2” [(BSPP), EN ISO 228-1]
Flange ASME
(EN/DIN)
19 to 100 mm (¾ to
4”)
Triclover-style 16
amp fitting
2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100)
Length
60 to 610 cm (24 to
240”)
60 to 610 cm (24 to
240”)
1 to 22.5 meters (3 to
75 ft)
1 to 22.5 meters (3 to 75 ft)
Transition zone:
Top
Blocking distance: 0
to 91 cm (0 to 36”),
probe length
dependent
Blocking distance: 12
to 91 cm (4.8 to 36”),
probe length
dependent
Blocking distance: 12
to 91 cm (4.8 to 36”),
probe length
dependent
Blocking distance: 12 to
91 cm (4.8 to 36”), probe
length dependent
Transition zone:
Bottom
25 mm (1”) @ dk
>
10 25 mm (1”) @ dk
>
10
305 mm (12”)
305 mm (12”)
Process
temperature
maximum
+150 °C @ 5.1 bar g
(+300 °F @ 75 psi g)
+150 °C @ 27 bar g
(+300 °F @ 400 psi g)
+150 °C @ 27 bar g
(+300 °F @ 400 psi g)
+66 °C @ 3.4 bar g
(+150 °F @ 50 psi g)
Process
temperature
minimum
0 °C at 5.1 bar g
(+32 °F at 75 psi g)
-40 °C @ 13.7 bar g
(-40 °F @ 200 psi g)
-40 °C @ 70 bar g
(-40 °F @ 1000 psi g)
-40 °C @ 3.4 bar g
(-40 °F @ 50 psi g)
Process
pressure
maximum
5.1 bar g @ +150 °C
(75 psi g @ +300 °F)
70 bar g @ +20 °C
(1000 psi g @ +70°F)
70 bar g @ +20 °C
(1000 psi g @ +70 °F)
3.4 bar g +66 °C
(50 psi g @ +150 °F)
Process
pressure
minimum/
vacuum service
Not suitable for vacuum applications
Dielectric range 1.9 to 100
1
1.9 to 100
1
4 to 100
1
4 to 100
Maximum
viscosity (cP)
10000 (consult factory if severe agitation/turbulence)
N/A
Coating/buildup Yes, maximum error 10% of coated length;% error related to dielectric of media, thickness of
coating and coated probe length above media
Содержание 7ML1301-1
Страница 1: ...Instruction Manual February 2009 LG200 sitrans ...
Страница 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Страница 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Страница 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Страница 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...