Siemens 7ML1301-1 Скачать руководство пользователя страница 26

Page 22

SITRANS LG200 – INSTRUCTION MANUAL 

7ML19985KA02

Specificat

ions

Model 7ML1303-1E (7xF-F) Probe, Flat-Faced Flanged Connection

Model 7ML1304-2 (7x2-x) Bulk Solids Flexible Probe, Threaded or Flanged 

Connection

1.  

Dependant on process connection. See “Probe Connections and Insertion Lengths” on 

page 26.

7ML1303-1E:

12 mm (0.5") rod diameter

7ML1303-1J:

16 mm (0.625") with PFA lining

60 mm 

(2.36")

probe insertion 

length D

80 mm 

(3.13")

83 mm 

(3.25")

Threaded 

process 

connection

mounting

flange

76 mm 

(3")

5 mm

(0.1875")

dia. cable

152 mm 

(6.00")

50 mm 

(2") dia.

probe 

insertion 

length

D

14.0 mm 
(0.55")

probe insertion length

1

B

A

2.25 kg (5 lbs)

AISI 316

weight

2.25 kg (5 lbs)

AISI 316

weight

Содержание 7ML1301-1

Страница 1: ...Instruction Manual February 2009 LG200 sitrans ...

Страница 2: ...d version and in electronic version We encourage users to purchase authorized bound manuals or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc Siemens Milltronics Process Instruments Inc will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions While we have verified the contents of this man...

Страница 3: ...er 35 Connecting SITRANS LG200 35 Connecting HART 36 Wiring setups for hazardous area installations 37 1 General Purpose or Non Incendive Wiring Class I Div 2 Installations 37 2 Intrinsically Safe Wiring 38 3 Explosion Proof Wiring 39 Instructions Specific to Hazardous Installations 39 General Probe Assembly Drawing for EEx d Applications 41 Quick Setup 42 Transmitter Display and Keypad 43 Operati...

Страница 4: ...opower Impulse Radar MIR 81 Time Domain Reflectometry TDR 81 Equivalent Time Sampling ETS 82 Interface Detection 82 Maximum Process Temperature Chart 83 Process Pressure Temperature Derating Curves 84 Appendix D Maintenance 85 Unit Repair and Excluded Liability 85 Appendix E HART Communications 86 SIMATIC PDM 86 HART Device Description EDD 86 HART Communicator 375 Menu Structure 87 Appendix F Intr...

Страница 5: ...inal Label on product yellow background WARNING refer to accompanying documents manual for details Caution Observe electrostatic discharge precautions prior to handling the device local user interface and display within the wiring compartment WARNING Changes or modifications not expressly approved by Siemens Milltronics could void the user s authority to operate the equipment Notes This equipment ...

Страница 6: ...utomation Process Instrumentation Level Measuring Instruments Select the team Technical Support Click Next Click the appropriate continent then select the country followed by the city Click Next For on line technical support go to www siemens com automation support request Enter the device name SITRANS LG200 or order number then click on Search and select the appropriate product type Click Next Yo...

Страница 7: ...afety approval DCS Distributed Control System control room apparatus dK dielectric constant ESD Electrostatic Discharge HART Highway Addressable Remote Transducer Communication protocol IS Intrinsically Safe safety approval μs microsecond 10 6 s PED Pressure Equipment Directive safety approval PV Primary Variable measured value SFF Safe Failure Fraction SIL Safety Integrity Level SV Secondary Vari...

Страница 8: ...asure Level Only Level and Volume Interface or Interface and Volume depending on probe selection SITRANS LG200 supports HART1 communication protocol and SIMATIC PDM software Programming SITRANS LG200 is very easy to install and configure using the 3 programing buttons on the device You can also program the LG200 using the HART hand held communicator or using SIMATIC PDM via HART Applications liqui...

Страница 9: ...1302 1xxxx xxxx 7xB x SITRANS LG200 Flexible Twin Rod Probe for Bulk Solids 7ML1302 2xxxx xxxx 7x5 x SITRANS LG200 Flexible Twin Rod Probe 7ML1302 3xxxx xxxx 7x7 x SITRANS LG200 Single Rigid Rod Probe 7ML1303 1xxxx xxxx 7xF x SITRANS LG200 Single Rigid Rod Probe Sanitary 7ML1303 1Dxx xxxx 7xF E SITRANS LG200 Single Rigid Rod Probe PFA faced flange 7ML1303 1Exx xxxx 7xF F SITRANS LG200 Single Rigid...

Страница 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...

Страница 11: ...obe length or 12 7 mm 0 5 whichever is greater resolution 2 5 mm 0 1 repeatability 2 5 mm 0 1 hysteresis 2 5 mm 0 1 Update time 1 second Influence of amb temperature 0 02 of probe length C Process dielectric effect 7 6 mm 0 3 within selected range Performance Interface Models Reference operating conditions according to reflection from liquid of selected dielectric at 20 C 70 F with 1829 mm 72 coax...

Страница 12: ...rements EN 61000 6 2 2001 61000 6 4 2001 Input measured variable level determined by time of flight of guided radar pulse from transmitter to product surface and back zero and span 15 cm to 22 86 m 6 to 75 ft user interface 3 button menu driven data entry and system security digital communication HART Version 5 x compatible Output mA Analog 4 to 20 mA with HART digital signal range Analog 3 8 to 2...

Страница 13: ... entry 2 x M20x1 5 or 2 x NPT ingress protection Type 4 NEMA 4 IP65 Weight2 transmitter with solid lid 1 48 kg 2 83 lbs with glass window lid 1 60 kg 3 52 lbs Environmental location indoor outdoor altitude 2000 m 6562 ft max ambient temperature 40 to 80 C 40 to 175 F relative humidity Type 4 NEMA 4 IP65 installation category II pollution degree 2 1 Display quality will be reduced in temperatures b...

Страница 14: ...d ø 45 mm 1 75 tube ø 15 mm 0 63 rod ø 45 mm 1 75 tube Process connection thread Standard Enlarged NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN ISO 228 1 2 NPT Taper ANSI ASME B1 20 1 NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN ISO 228 1 2 NPT Taper ANSI ASME B1 20 1 NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN ISO 228 1 2 NPT Taper ANSI ASME B1 20 1 NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN ISO 228 1 2 NPT Taper...

Страница 15: ...minimum vacuum service Yes not hermetic2 Yes hermetic 10 8 cc sec 1 atmosphere Yes hermetic 10 8 cc sec 1 atmosphere Yes not hermetic Dielectric range 1 4 to 100 1 4 to 100 1 4 to 100 1 4 to 100 Maximum viscosity cP Standard Enlarged 500 1500 500 1500 500 1500 500 1500 Coating buildup No No No No Foam No No No No Corrosives Yes Yes Yes Yes Sanitary No No No No Overfill No Yes No Yes 1 See O Ring S...

Страница 16: ...PF128 O ring only2 O ring2 Rod Tube diameter Standard ø 8 mm 0 3125 rod ø 22 mm 0 875 tube ø 8 mm 0 3125 rod ø 22 mm 0 875 tube ø 12 mm 0 5 rod ø 12 mm 0 5 rod ø 12 mm 0 5 rod ø 16 mm 0 625 insulation Enlarged N A ø 15 mm 0 63 rod ø 45 mm 1 75 tube N A N A N A Process connection thread Standard Enlarged NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN ISO 228 1 N A NPT Taper ANSI ASME B1 20 1 G 1 BSPP EN I...

Страница 17: ... 20 C 1000 psi g 70 F 207 bar g 20 C 3000 psi g 70 F 70 bar g 20 C 1000 psi g 70 F Process pressure minimum vacuum service Yes not hermetic Yes not hermetic Not suitable Not suitable Not suitable Dielectric range 10 to 100 Upper liquid layer 1 4 to 5 Interface liquid layer 15 to 100 1 9 to 1001 1 9 to 1001 1 9 to 1001 Maximum viscosity Standard Enlarged 500 cP N A 500 cP 1500 cP 10000 cP consult f...

Страница 18: ... to 4 Triclover style 16 amp fitting 2 to 4 DN 50 to 100 2 to 4 DN 50 to 100 2 to 4 DN 50 to 100 Length 60 to 610 cm 24 to 240 60 to 610 cm 24 to 240 1 to 22 5 meters 3 to 75 ft 1 to 22 5 meters 3 to 75 ft Transition zone Top Blocking distance 0 to 91 cm 0 to 36 probe length dependent Blocking distance 12 to 91 cm 4 8 to 36 probe length dependent Blocking distance 12 to 91 cm 4 8 to 36 probe lengt...

Страница 19: ...ifications Foam Yes Yes Yes Yes Corrosives No Yes No No Sanitary Yes No No No Overfill No No No No 1 With dK of 1 9 to 10 the device must be mounted between 50 and 150 mm 2 to 6 of metal tank wall or in chamber bridle 2 See O ring Selection Guide for guidance ...

Страница 20: ...Flange ASME EN DIN 2 to 4 DN 50 to 100 2 to 4 DN 50 to 100 2 to 4 DN 50 to 100 Length 60 to 610 cm 24 to 240 1 to 22 5 m 3 to 75 ft 1 to 22 5 m 3 to 75 ft Transition zone2 Top 2 Transition zone is dielectric dependent dK dielectric permittivity Unit will function but accuracy will decrease in Transition Zone 150 mm 6 dK 1 9 Blocking distance none 150 mm 6 dK 1 9 Blocking distance 12 to 50 cm 4 8 t...

Страница 21: ...ez 4079 200 C 16 bar g 400 F 232 psi g 40 C 40 F Inorganic and organic acids including HF and nitric aldehydes ethylene glycols organic oils silicone oils vinegar sour HCs Black liquor hot water steam hot aliphatic amines ethylene oxide propylene oxide molten sodium molten potassium anhydrous ammonia Aegis PF128 200 C 16 bar g 400 F 232 psi g 20 C 4 F Inorganic and organic acids including HF and n...

Страница 22: ... 2 Groups E F G FM Class I Div 2 Groups A B C D Class II Div 2 Groups F G Europe General Purpose and Intrinsically Safe ATEX II 1G EEx ia IIC T4 Explosion Proof ATEX II 1 2 GD EEx d ia IIC T6 Non sparking ATEX II 3G EEx nA II EEx nA nL IIC T4 to T6 Safety Integrity Level SIL SIL 1 Transmitter 7ML1300 xxAxx xxxx Safe Failure Fraction SFF 85 5 SIL 2 Transmitter 7ML1300 xxBxx xxxx Safe Failure Fracti...

Страница 23: ...be Connections and Insertion Lengths on page 26 Note Threaded process connections dimensions are NPT unless otherwise stated M20 135 mm 5 32 NPT 150 mm 5 91 2 cable entries NPT or M20x1 5 lid with window lid without window 166 mm 6 54 153 mm 6 02 38 mm 1 5 enclosure process connection process connection 59 mm 2 32 probe insertion length D 74 mm 2 91 145 mm 5 7 120 mm 4 7 14 0 mm 0 55 A B probe ins...

Страница 24: ...D 7xF E Probe Sanitary Connection 1 Dependant on process connection See Probe Connections and Insertion Lengths on page 26 57 mm 2 24 probe insertion length1 12 mm 0 5 dia rod optional spacer 7ML1930 1DJ 14 0 mm 0 55 12 mm 0 5 dia rod probe insertion length D 60 mm 2 36 B A optional spacer 7ML1930 1DJ 12 mm 0 5 dia rod probe insertion length C 60 mm 2 36 ...

Страница 25: ...ocess connection mounting flange 610 mm 24 5 mm 0 1875 dia cable 99 mm 3 88 57 mm 2 25 25 mm 1 450 g 1 lb TFE weight 50 mm 2 dia 12 mm 0 5 dia hole 19 mm 0 75 probe insertion length D 14 0 mm 0 56 450 g 1 lb TFE weight probe insertion length1 A B 71 mm 2 80 44 mm 1 75 Threaded process connection mounting flange 76 mm 3 5 mm 0 1875 dia cable 99 mm 3 88 57 mm 2 25 32 mm 1 25 284 g 10 oz TFE weight 5...

Страница 26: ...rocess connection See Probe Connections and Insertion Lengths on page 26 7ML1303 1E 12 mm 0 5 rod diameter 7ML1303 1J 16 mm 0 625 with PFA lining 60 mm 2 36 probeinsertion length D 80 mm 3 13 83 mm 3 25 Threaded process connection mounting flange 76 mm 3 5 mm 0 1875 dia cable 152mm 6 00 50 mm 2 dia probe insertion length D 14 0 mm 0 55 probe insertion length1 B A 2 25 kg 5 lbs AISI 316 weight 2 25...

Страница 27: ...ion See Probe Connections and Insertion Lengths on page 26 Threaded process connection 126 mm 4 96 probe insertion length D 129 mm 5 08 20 3 mm 0 80 Threaded process connection probe insertion length1 B A Threaded process connection 80 mm 3 13 83 mm 3 25 mounting flange 76 mm 3 0 76 mm 3 0 5 mm 0 1875 dia cable 50 mm 2 dia 152mm 6 20 3 mm 0 80 2 25 kg 5 lbs AISI 316 weight 2 25 kg 5 lbs AISI 316 w...

Страница 28: ...1 3 Coaxial HP Probe 106 mm 4 18 166 mm 6 54 7ML1301 4 Coaxial Overfill Flooded Cage Probe 7ML1301 6 Coaxial Interface Probe 150 mm 5 89 167 mm 6 57 7ML1301 5 Coaxial HT HP Steam Probe 180 mm 7 10 242 mm 9 52 Note Refer to the Model Number chart on page 5 to cross reference the reference number appearing on the probe to the actual Probe model number 22 2 mm 0 875 ø 13 mm 0 5 dia rod 10 mm 36 mount...

Страница 29: ...T optional sight glass connections midrange midrange min 1 102 mm 4 1 min 2 110 mm 4 3 max level range min 356 mm 14 max 6 1 m 240 max level range min 356 mm 14 max 6 1 m 240 max level range min 356 mm 14 max 6 1 m 240 midrange midrange min 76 mm 3 min 76 mm 3 min 76 mm 3 min 76 mm 3 min 1 64mm 2 5 min 2 86 mm 3 4 min 94 mm 3 7 ...

Страница 30: ...ANUAL 7ML19985KA02 Specifications Probe Connections and Insertion Lengths Note BSP connections differ from NPT NPT BSP sanitary flange ANSI or DIN welded flange insertion length A insertion length B insertion length C insertion length D ...

Страница 31: ...ng a nozzle or spool piece to raise the probe Consult factory to ensure proper installation Materials of construction are chosen based on their chemical compatibility or inertness for general purposes For exposure to specific environments check with chemical compatibility charts before installing The user is responsible for the selection of bolting and gasket materials which will fall within the l...

Страница 32: ...able transition is not available at the process connection When using single rod versions flexible or solid and a threaded process connection a metal sheet or flange will greatly improve conditions as this provides a suitable launch plate A flanged process connection is generally accepted to be provision of this launch plate Notes Each SITRANS LG200 is built to match the specific physical specific...

Страница 33: ...odel 7ML1301 5 Steam probe and Model 7ML1301 6 Interface probe require added clearance Process temperature pressure dielectric and viscosity are within the probe specifications for the installation Handle Model 7ML1301 2 High Temperature High Pressure probes with extra care WARNING Do not disassemble probe when in service and under pressure High Level or Overfill Applications The Model 7ML1301 2 7...

Страница 34: ... the process connection is at least 2 NPT or a flanged mounting 2 Make sure that there is at least 25 mm 1 spacing between the active probe rod and any part of the tank walls still well pipes support beams mixer blades etc Minimum stillwell or nozzle diameter for Twin Rod probe is 80 mm 3 3 Carefully place the probe into the vessel Align the gasket on flanged installations 4 Align the probe proces...

Страница 35: ...Loosen the two 10 32 set screws on both securing devices using a 3 32 2 5 mm hex wrench and slide the securing devices off of the probe c Slide the TFE weight off of the probe d Cut and remove the required cable length e Remove 89 mm 3 of the rib between the two cables f Strip 16 mm 5 8 of coating from the two cables g Slide the TFE weight back on to the probe h Reattach securing device and tighte...

Страница 36: ...field a Raise TFE weight exposing securing device b Loosen both 10 32 set screws using 2 5 mm 0 1 hex wrench and remove securing device c Cut and remove needed cable length d Reattach securing device and tighten screws e Enter new probe length inches or cm in length parameter Probe can be attached to the tank bottom using the 13 mm 0 50 diameter hole provided in the TFE weight Cable tension should...

Страница 37: ...nnection is at least 2 NPT or a flanged mounting 2 Make sure that there is at least 25 mm 1 spacing between the active probe rod and any part of the tank walls stillwell pipes support beams mixer blades etc Minimum stillwell diameter for Twin Rod probe is 76 mm 3 3 Carefully place the probe into the vessel Align the gasket on flanged installations 4 Align the probe process connection with the thre...

Страница 38: ...or cm in software Installing the Transmitter 1 Remove the protective plastic cap from the top of the probe Put the cap in a safe place in case the transmitter has to be removed later 2 Place the transmitter on the probe Be careful not to bend or dirty the gold high frequency male connector 3 Align the universal connection at the base of the transmitter housing with the top of the probe Hand tighte...

Страница 39: ... only be performed by qualified personnel and in accordance with local governing regulations All HART versions of SITRANS LG200 transmitter operate at voltages of 11 to 36 V DC at the device terminals Higher voltage will damage the transmitter Notes Use shielded twisted pair cable 0 5 to 1 mm AWG 22 to 18 WARNING Check the nameplate on your instrument to verify the approval rating Note Use shielde...

Страница 40: ... the HART protocol a 250 Ohm resistor may be required if the loop resistance is less than 250 Ohms Only one HART communication device should be inserted in the loop PLC with mA input card PC laptop with HART modem running PDM HART Communicator 375 SITRANS LG200 power supply R 250 Ohms Loop Voltage versus Loop Resistance 650 24 V DC 20 mA 23 mA V DC Ω 11 ...

Страница 41: ...t to ensure a liquid tight connection 3 Install a conduit fitting and feed the supply wires into the SITRANS LG200 through the conduit entry 4 Connect shield to an earth ground at power supply 5 Connect an earth ground wire to the nearest green ground screw 6 Connect the positive supply wire to the terminal and the negative supply wire to the terminal 7 Replace the enclosure lid Note Electrical da...

Страница 42: ...arth ground at power supply 6 Connect an earth ground wire to the nearest green ground screw 7 Connect the positive supply wire to the terminal and the negative supply wire to the terminal 8 Replace the enclosure lid Note Electrical data for SITRANS LG200 Level Transmitter Model 7ML1300 1Axx1 xCA0 Output supply circuit terminals and in type of protection intrinsic safety EEx ia IIC only for connec...

Страница 43: ...e hazardous and safe areas In European applications an Ex d gland is required at the conduit connection of the transmitter 1 Install Explosion Proof conduit from the safe area to the conduit connection of the SITRANS LG200 transmitter refer to local plant or facility procedures 2 Remove the cover to the wiring compartment of the transmitter 3 Connect shield to an earth ground at the power supply 4...

Страница 44: ...e category 1G apparatus is required electrostatic charges on the non metallic parts of the Probe Model 7ML1302 2 7x5 Model 7ML1302 3 7x7 and Model 7ML1303 7xF shall be avoided For KEMA 07ATEX0077 X Installation instructions For use in potentially explosive atmospheres of flammable gases fluids or vapors The cable entry devices and the closing elements of unused apertures shall be of a certified fl...

Страница 45: ...5E01184944 2 RA RPC 1 2 SM SM JUNE 07 07 JULY 09 2007 LID KEMA 00ATEX2039X PCB BOARD STACK KEMA 07ATEX0075X E x d HOUSING E KEMA 00ATEX2039X BUSHING THE BUSHING SHALL BE SECURED AGAINST LOOSENING E G BY USING A SUITABLE SEALANT DO NOT EXCEED 100 KEMA 99ATEX5311 C AT HOUSING PROBE KEMA 99ATEX0518X 99ATEX5311 CABLE PROBE TWIN ROD PROBE NOTES 1 EEx d IP66 CABLE GLAND IS REQUIRED TO MAINTAIN x d APPLI...

Страница 46: ...ormation at top of probe Note Y01 xxx cm ____________________ 6 Level Offset desired level reading when liquid is at the end of the probe _________ 7 Dielectric dielectric constant range of process medium upper layer dielectric for interface applications _________________________ 8 Loop Control Is output current to be controlled by level or volume ______________ 9 Set 4 0 mA1 What is the reference...

Страница 47: ...ep of the configuration process the default password is 0 7 To return to RUN mode scroll to the display parameters Status 8 After entering the last value allow 10 seconds before removing power from the transmitter save function Transmitter Display and Keypad The SITRANS LG200 transmitter has a liquid crystal display LCD capable of showing two lines of 8 characters each Transmitter measurements and...

Страница 48: ...ne display to another In PROGRAM mode these keys increase or decrease the value displayed and move to the next choice Hold the Arrow Key for rapid scrolling Enter Key In RUN mode press Enter to switch to PROGRAM mode shows an exclamation point as the last character in the top display line In PROGRAM mode press ENTER to accept a value and move to the next step of the programming ...

Страница 49: ...rend Monitoring Electronic Device Description EDD You can locate the EDD in Device Catalog under Sensors Level Echo Siemens Milltronics SITRANS LG200 Check the product page of our website at https pia khe siemens com index asp Nr 15361 under Downloads to make sure you have the latest version of SIMATIC PDM the most recent Service Pack SP and the most recent hot fix HF If you need to install a new ...

Страница 50: ...necessary download it from the product page listed above Save the files to your computer and extract the zipped file to an easily accessed location Launch SIMATIC PDM Options Manage Device Catalog browse to the unzipped EDD file and select it 2 Launch SIMATIC Manager and create a new project for LG200 Application Guides for setting up HART and PROFIBUS PA devices with SIMATIC PDM can be downloaded...

Страница 51: ... If you have not already done so check that you have the most up to date Device Description EDD for your instrument See Configuring a new device on previous page 2 Launch SIMATIC Manager and create a new project for LG200 Application Guides for setting up HART devices with SIMATIC PDM can be downloaded from the product page of our website at https pia khe siemens com index asp Nr 11813 3 Program t...

Страница 52: ...ed to 16 characters and Message field is limited to 30 characters Step 2 Application Select the probe model probe mount and probe length and then define the level settings level unit level offset and blocking distance if required Then select the appropriate dielectric range from the drop down list Click on NEXT Note The layout of the dialog boxes shown may vary according to the resolution setting ...

Страница 53: ...Select the application switch level level and volume interface interface volume from the drop down list Click on NEXT Step 4 Ranges Set start of scale 4 mA full scale 20 mA and damping values The primary variable is selected in step 3 and the level units are selected in step 2 Click on Next ...

Страница 54: ...aunch SIMATIC PDM connect to SITRANS LG200 and upload data from the device 2 Adjust parameter values in the parameter value field then press Enter The status fields read Changed 3 Open the Device menu click on Download to device then use File Save to save parameter settings The status fields are cleared Notes For a complete list of parameters see Parameter Reference on page 57 Clicking on Cancel d...

Страница 55: ...ho profile Open the menu Device Echo Profile Utilities Click on the Echo Profile tab Click on the Measure button to update the profile To save the echo profile click Save and in the new window enter a name and click OK Click OK to exit Notes Double click on each axis to see the X scale and Data Scale values Click on the axis and drag to reposition the scale After saving a profile click on OK not t...

Страница 56: ...ter the desired interval between stored profiles Enter the desired number of profiles to be stored maximum 50 Click on Start A message appears warning of the time delay and warning that all previous saved profiles will be overwritten Click on OK to proceed The new profiles will be saved with their date and time View Saved Echo Profiles To view a saved profile in the Echo Profile Utilities window c...

Страница 57: ...e menu Device Configuration Flag Reset and execute a reset Trim Loop Current Allows you to trim the 4 mA and 20 mA points in order to calibrate the mA output Open the menu Device D A Trim You will be prompted to attach a calibrated meter and enter the values at 4 mA and at 20 mA Notes Double click on each axis and record the Xscale and Data Scale values so that you can restore the default view by ...

Страница 58: ...he menu Device Loop Test 2 Select Other enter the new value and click on OK The message Field Device fixed at new value appears Click on OK 3 When you are ready to end simulation select End and click on OK to return the device to the original output level Self Test Allows you to complete a self test function with the unit 1 Open the menu Device Self Test 2 Select Yes and the device will execute a ...

Страница 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...

Страница 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...

Страница 61: ...ser parameters below or listed in Appendix A Alphabetical Parameter List on page 72 Display loop Run Mode Display Options Status If you choose Status the LG200 display will show Status Level Output and Loop and or Volume and or Interface Level and or Interface Volume values cycling every two seconds Level Displays level value in selected units Values View only Status Level or Volume or IfcLvl or I...

Страница 62: ...er password In Program Mode when the proper user password is entered an exclamation point is the last character of the first line of the display The user password can be changed to any numerical value up to 255 The password is required whenever configuration values are changed The default user password is 0 Enter a new password in the last step of the configuration menu With a password of 0 the tr...

Страница 63: ...t Sets probe mounting type User password NOTE If the user password is not known the menu item New Password displays an encrypted value representing the present password Call the factory with this encrypted value to determine the present password NOTE Parameters described in the following are dependant on probe type Default values may change according to probe type This will assist with set up of t...

Страница 64: ...oint Enter desired reading when probe is dry User password Offset Description The parameter referred to as Lvl Ofst in the SITRANS LG200 menu is the desired level reading when liquid surface is at the end of the probe The LG200 transmitter is shipped from the factory with Lvl Ofst set to 0 With this configuration all measurements are referenced from the bottom of the probe See Example 1 Example 1 ...

Страница 65: ...0 Application calls for a 72 NPT coaxial probe in water with the bottom of the probe 10 above the bottom of the tank The user wants the 4 mA point at 24 and the 20 mA point at 60 as referenced from the bottom of the tank When the SITRANS LG200 transmitter is mounted in a chamber bridle the unit is usually configured with the 4 mA 0 point at the lower process connection and the 20 mA 100 point at t...

Страница 66: ...e User password Strapping Table Breakpoints SITRANS LG200 is available with a 20 point custom strapping table Up to 20 pairs of Level Volume points can be entered to linearize the 4 to 20 mA output for odd shaped vessels There are two ways to enter data into the strapping table Procedure 1 this method is the most common 1 Select Level and Volume as the Measurement Type 2 Ensure that the correct Le...

Страница 67: ... enter 4 Add a known liquid volume to the vessel 5 For the remaining points add a known liquid volume to vessel and repeat steps 2 to 3 Dielectric Dielctrc Select range bounding the dielectric constant of the media The LG200 uses this dielectric setting to adjust the Sensitivity setting User password The lower the dielectric setting the higher the sensitivity In applications where the dielectric m...

Страница 68: ...t Output Loop Control Loop Ctrl Select variable to control loop current mA output User password 1 4 1 7 1 7 3 3 10 10 100 7ML1301 1 7ML1301 2 7ML1301 3 7ML1301 4 7ML1301 5 7ML1304 1 7ML1301 6 Upper Liquid Layer 1 4 5 Interface Liquid Layer 15 to 100 7ML1303 1 7ML1303 2 7ML1303 1J 7ML1303 1D 7ML1303 1B 7ML1302 1 7ML1302 3 7ML1302 2 1 9 to 100 7ML1304 2 4 to 100 Values Enter value upward or downward...

Страница 69: ...l is below the setpoints and 20 5 mA when level is above the setpoints User password The 20 mA can also be 0 of the level depending on the configuration Note Dependant on probe a small transition zone 0 to 15 cm 6 may exist at the top bottom of the probe Damping Damping A Damping factor 0 10 seconds can smooth a noisy display and or output due to turbulence User password For example if damping is ...

Страница 70: ...he blocking distance Safety Zone Fault SZ Fault Select loop current behavior when level is sensed in safety zone Safety Zone is a user defined area just below the Blocking Distance Enable Fault if necessary to ensure safe reliable high level readings in critical applications User password If Latch 3 6 or Latch 22 is chosen the loop current will remain in alarm until it is manually cleared with the...

Страница 71: ...ns Poll Address Poll Adr Enter HART polling address number User password Trim Level Trim Lvl Enter value to adjust level reading Used to adjust for mounting installation effects with single rod probes User password Trim 4 mA Trim 4 Adjust setting to output exactly 4 0 mA User password Attach a current meter into the loop Adjust the trim until the meter reads 4 00 mA The value of Trim mA is typical...

Страница 72: ...abilities 9999 on long probes Interface Ticks Ifc Ticks Time of flight through upper liquid Medium Applicable only when Ifc Ifc Vol selected Provides information on interface layer based on analog waveform New Password New Pass Displays encrypted value of present password To retrieve forgotten password contact factory with encrypted value Then enter new password User password Language Language Lan...

Страница 73: ...rom reference point to measured point This value can be converted from equivalent time to real distance via calculations Fiducial Spread Fid Sprd factory authorized personnel only Variability measure of Fiducial Ticks Fiducial Type Fid Type factory authorized personnel only Default negative Select from positive or negative only available on selected probe models Superuser password required Fiducia...

Страница 74: ...mplitude Pos Ampl factory authorized personnel only Default 60 Diagnostic parameter Controls the threshold setting for detection of the positive end of probe signals Changing probe model or dielectric range will adjust amplitude correctly Superuser password required Signal Signal factory authorized personnel only Indication of level signal amplitude with respect to the CFD Constant Fraction Discri...

Страница 75: ...int 7ML1305 1 probe characteristic Superuser password required Electronics Temperature Elec Temp factory authorized personnel only Present temperature in electronics compartment degrees Celsius Maximum Temperature Max Temp factory authorized personnel only Maximum electronics temperature recorded Minimum Temperature Min Temp factory authorized personnel only Minimum electronics temperature recorde...

Страница 76: ...personnel only 71 Default 0 0 Superuser password Blocking Distance BlockDis 66 Default 0 cm User password Compensate Compsate factory authorized personnel only 70 Default None Superuser password Conversion Factor Conv Fct factory authorized personnel only 69 Default 985 Factory password Damping Damping 65 Default 0 sec User password Volume Units Vol Units 62 Default gallons User password Level Uni...

Страница 77: ...Ticks Ifc Ticks 68 Language Language 68 Default English User password Level Offset Lvl Ofst 60 Default 0 in User password Level Ticks Lvl Ticks 68 Loop Test mA Loop Tst 68 Maximum Temperature Max Temp factory authorized personnel only 71 Medium 68 Minimum Temperature Min Temp factory authorized personnel only 71 Negative Amplitude Neg Ampl factory authorized personnel only 70 Default 36 Superuser ...

Страница 78: ...uperuser password Strapping Table Breakpoints 62 Default 0 0 Strapping Table StrapTbl 62 Default Pt Lvl 0 0 cm Pt Vol 0 0 g User password Target Calibration Lvl only factory authorized personnel only 1 70 Default 1000 Threshold Threshld 67 Default Fixed User password Trim 20 mA Trim 20 67 Default 3266 User password Trim 4 mA Trim 4 67 Default 651 User password Trim Level Trim Lvl 67 Default 0 0 in...

Страница 79: ...Probe Model and probe length Adjust trim level by the amount of noted inaccuracy Level Output and Loop values fluctuate Turbulence High Frequency connection Increase the Damping factor until the readings stabilize Check Fid Spread should be stable within 10 counts Level Output and Loop values all read ing low vs actual Lower dielectric material over higher dielectric mate rial e g oil over water C...

Страница 80: ...ction Level value reading high when should be zero Transmitter loose or discon nected from probe Ensure transmitter connected securely to probe Display message Action Comment OK None Normal Operating Mode Initial None Program is initializing level reading held at 4 mA setpoint This is a tran sient condition DryProbe None Normal message for dry probe End of probe signal is being detected EOP Low En...

Страница 81: ...eck for damaged gold pin on the high frequency connector Consult factory Fid Sprd Fiducial Ticks variation is excessive Check connection between probe and transmitter Check for moisture on top of probe Consult factory SZ Alarm Safety Zone alarm has been tripped loop current fixed at SZ fault Decrease level in vessel Hi Temp Present temperature in electronics compartment is above 80 C 176 F Transmi...

Страница 82: ...ting improper voltage Consult factory LoopFail Loop current differs from expected value Consult factory No Ramp No End of Ramp signal detected Consult factory DfltParm Internal non volatile parameters have been defaulted Consult factory EE Fail EEPROM error allowing watch dog timer to expire Consult factory CPU Fail A D converter time out allowing watch dog timer to expire Consult factory SfwrFail...

Страница 83: ... can develop if the product begins to build up on the spacers that separate the probe elements High dielectric media e g water based will cause the greatest error Bridging Media that is viscous or solid enough to form a clog or bridge between the elements causes the greatest degradation in performance High dielectric media e g water based will show as level at the location of the bridging Stratifi...

Страница 84: ... nozzle Increasing the DIELECTRIC setting reduces the gain which may cause instrument to lose level of lower dielectric media consult factory Obstructions If the level reading repeatedly locks on to a specific level higher than the actual level it may be caused by a metallic obstruction Obstructions in the vessel e g pipes ladders that are located close to the probe may cause the instrument to sho...

Страница 85: ... the greater the amplitude strength of the reflection In telephone computer and power transmission industries it is used to successfully find wire or cable breaks and shorts An EM pulse is sent through the wire traveling unimpeded until it finds a line break or short A reflection is then returned from the break enabling a timing circuit to pinpoint the location In the SITRANS LG200 transmitter a w...

Страница 86: ...ctive with a dielectric constant of approximately 2 and the lower layer of water being very conductive with a dielectric constant of approximately 80 This interface measurement can only be accomplished when the dielectric constant of the upper medium is lower than the dielectric constant of the lower medium SITRANS LG200 Guided Wave Radar is based upon the technology of TDR Time Domain Reflectomet...

Страница 87: ... for those applications where the thickness of the upper layer is greater than 2 inches The maximum upper layer is limited to the length of the Model 7ML1301 6 probe which is available in lengths from 60 to 610 cm 24 to 240 Emulsion Layers As emulsion rag layers can decrease the strength of the reflected signal the SITRANS LG200 should only be used in applications that have clean distinct layers C...

Страница 88: ...ION MANUAL 7ML19985KA02 Technical Reference Process Pressure Temperature Derating Curves Note Above charts represent threaded process connections only Flanged process connections should be derated according to ASME EN JIS standards ...

Страница 89: ... solution that will not react adversely with either Remove the device from service and wipe the probe clean using a cloth and suitable cleaning solution Unit Repair and Excluded Liability All changes and repairs must be done by qualified personnel and applicable safety regulations must be followed Please note the following The user is responsible for all changes and repairs made to the device All ...

Страница 90: ...is software package is designed to permit easy configuration monitoring and troubleshooting of HART devices The HART EDD for SITRANS LG200 was written with SIMATIC PDM in mind and has been extensively tested with this software For more information see Operating via SIMATIC PDM on page 45 HART Device Description EDD In order to configure a HART device the configurator must have the HART Device Desc...

Страница 91: ... SETPOINT 20 mA SETPOINT DAMPING SYSTEM FAULT STATE BLOCKING DISTANCE SZ FAULT STATE SZ HEIGHT SZ ALARM RESET THRESHOLD INTERFACE PARAMETERS UPPER DIELECTRIC INTERFACE THRESHOLD INTERFACE THRESHOLD AMPLITUDE TRIM LEVEL DATE TIME INITIALS BASIC SETUP TAG DESCRIPTOR DATE MESSAGE POLL ADDRESS FINAL ASSEMBLY NUMBER ADVANCED SETUP TRIM LOOP CURRENT ENTER PASSWORD FIDUCIAL TYPE SERIAL NUMBER DEVICE ID W...

Страница 92: ...N FACTORY SETTINGS SZ HYSTERESIS MAX TEMPERATURE MIN TEMPERATURE RESET TEMPERATURES NEW USER PASSWORDS DIAGNOSTICS LOOP TEST PRESENT STATUS FAULTS SOFTWARE FAILURE CPU FAILURE NV MEMORY FAILURE DEFAULT PARAMETERS NO END OF RAMP NO PROBE NO FIDUCIAL NO SIGNAL LOOP FAILURE FIDUCIAL SHIFT SLOPE ERROR CHANNEL UNBALANCED HI VOLUME ALARM SAFE ZONE ALARM FAULT 15 FAULT 16 WARNINGS FIDUCIAL SPREAD HI TEMP...

Страница 93: ...MBER FIRMWARE VERSION TAG DESCRIPTOR DATE MESSAGE POLL ADDRESS FINAL ASSEMBLY NUMBER DEVICE ID PROBE MODEL PROBE MOUNT MEASUREMENT TYPE LEVEL UNITS PROBE LENGTH LEVEL OFFSET VOLUME UNITS DIELECTRIC RANGE SENSITIVITY PV IS SV IS TV IS QV IS 4 mA SETPOINT 20 mA SETPOINT DAMPING SYSTEM FAULT STATE BLOCKING DISTANCE SZ FAULT STATE SZ HEIGHT THRESHOLD INTERFACE THRESHOLD INTERFACE THRESHOLD AMPLITUDE T...

Страница 94: ...munications POSITIVE THRESHOLD AMPLITUDE COMPENSATION MODE UPPER DIELECTRIC 7ML1305 1 CORRECTION SZ HYSTERESIS UNIVERSAL REV FIELD DEV REV SOFTWARE REV NUMBER REQ PREAMS PV LEVEL OR VOL PV OUT PV LOOP DEVICE VARIABLES LEVEL VOLUME INTERFACE LEVEL INTERFACE VOLUME ...

Страница 95: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 91 Hazardous Installation Appendix F Intrinsically Safe Installation ...

Страница 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...

Страница 97: ...probe bulk solids 33 bulk solids flexible single rod 33 bulk solids flexible twin rod 33 flexible twin rod 31 single flexible rod 32 single rigid rod 31 installing transmitter 34 interface performance 7 intrinsically safe wiring 38 K key function 44 keypad 43 L level performance 7 level offset 60 LG200 model chart 5 overview 4 loop display 57 M maintenance 85 cleaning 85 manual 2 model parameter 5...

Страница 98: ...SIMATIC PDM 45 Quick Start 47 specifications 7 environmental 9 input 8 output 8 performance 7 power 7 process conditions 18 strapping table 62 T technical reference 81 technical support contact information 2 temperature derating curves 84 transmitter display 43 troubleshooting application 75 W wiring 35 explosion proof 39 general purpose 37 intrinsically safe 38 ...

Страница 99: ...ltronics Process Instruments Inc 1954Technology Drive P O Box 4225 Peterborough ON Canada K9J 7B1 Tel 705 745 2431 Fax 705 741 0466 Email techpubs smpi siemens com Siemens Milltronics Process Instruments Inc 2007 Subject to change without prior notice Printed in Canada ...

Отзывы: