8
Pulse output 2 overflow > PF [Hz] pulse output 2 overflow
9
Consumption interval warning (alarm limits are configurable)
L
Leakage warning (alarm limits are configurable)
E
Empty pipe / low conductivity - when enabled*
C
High conductivity / low impedance warning (alarm limits are configurable)
d
High flow rate warning (alarm limits are configurable)
A
Reverse high flow rate warning (alarm limits are configurable)
*) Meter disables measurement to reduce power consumption during fatal faults.
Index 5
Customer totalizer
Figure 7-10
Operator menu - Totalizer
For the CT version the totalizer is neither configurable nor resttable.
Display test
Figure 7-11
Operator menu - Display test
All segments of display are alternately flashed on and off during this test.
Operating
7.4 Operator menu
SITRANS FM MAG 8000