Param‐
eter ID
Meter
version
Display
view
Parameter/data type
Factory settings
Data range
Fixed parameter or meter data that are not changeable
202
All
-
Date of fault log reset
PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
203
All
O4
Non optimal measure time, in‐
cluding the time of device run‐
ning with insulation test fault,
coil current fault, amplifier
fault, database checksum
fault, flow overload fault, or
empty pipe fault.
0
204
All
-
Reset the fault log and faults
No
Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
205
All
-
Call up acknowledge
No
Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
206
All
-
Battery alarm level
10%
0 to 100%
208
All
-
Reset leakage fault
No
Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
209
All
-
Reset consumption log fault
No
Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
210
All
-
Insulation alarm output enable No
Yes / No
211
All
-
Insulation fault hours
0
212
All
-
Insulation fault counter
0
213
All
-
Insulation fault appears
2000-01-01 T 00:00:00
214
All
-
Insulation fault disappears
2000-01-01 T 00:00:00
215
All
-
Coil current alarm output ena‐
ble
Yes
Yes / No
216
All
-
Coil current fault hours
0
217
All
-
Coil current fault counter
0
218
All
-
Coil current fault appears
2000-01-01 T 00:00:00
219
All
-
Coil current fault disappears
2000-01-01 T 00:00:00
220
All
-
Amplifier alarm output enable Yes
Yes / No
221
All
-
Amplifier fault hours
222
All
-
Amplifier fault counter
223
All
-
Amplifier fault appears
2000-01-01 T 00:00:00
224
All
-
Amplifier fault disappears
2000-01-01 T 00:00:00
225
All
-
Database alarm output enable Yes
Yes / No
226
All
-
Database fault hours
0
227
All
-
Database fault counter
0
Parameter lists
F.3 200-299
SITRANS FM MAG 8000
144
Operating Instructions, 03/2020, A5E03071515-AH
Содержание 7ME6810
Страница 10: ...Introduction 1 7 Notes on warranty SITRANS FM MAG 8000 10 Operating Instructions 03 2020 A5E03071515 AH ...
Страница 16: ...Description 3 4 Benefits SITRANS FM MAG 8000 16 Operating Instructions 03 2020 A5E03071515 AH ...
Страница 76: ...Operating 7 6 Battery powered operation SITRANS FM MAG 8000 76 Operating Instructions 03 2020 A5E03071515 AH ...
Страница 86: ...Service and maintenance 8 9 Disposal SITRANS FM MAG 8000 86 Operating Instructions 03 2020 A5E03071515 AH ...
Страница 140: ...Unit conversion table SITRANS FM MAG 8000 140 Operating Instructions 03 2020 A5E03071515 AH ...
Страница 168: ...Features SITRANS FM MAG 8000 168 Operating Instructions 03 2020 A5E03071515 AH ...