6
05.01
6.7 DC link options
6-192
©
Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
When supplied:
Connector with a jumper between 1R and 2R
internal resistor active
P600
M600
PR module
2R
3R
1R
X151
X351
19
50
X221
DC link fast
discharge
PE
Thermally conductive
plate
1)
P600
M600
PR module
2R
3R
1R
X151
X351
19
50
X221
DC link fast
discharge
PE
PE
Shield connecting plate
Connecting an external resistor:
Connector without jumper
Internal resistor is not active
External resistor is active
With internal pulsed resistor
With external pulsed resistor
1) Installation, see Chapter 12, Fig. 12-63
Fig. 6-21
PR module, Order No.: 6SN1113–1AB01–0BA
Note
Only the external PR 6SL3 100–1BE22–5AA0 can be connected.
Notice
Fast discharge is possible only when a 3–phase AC line supply is present!
Connection
PR module
6 Infeed Modules