Technical specifications
7.3 Interface description
Carrier controller
44
Operating Instructions, 09/2013, A5E03474162-02
7.3
Interface description
7.3.1
Connectors and cables
The power and data cables for the carrier controller are installed using connectors and
sockets of Harting Technology Group. See chapter "Accessories (Page 10)".
7.3.2
Interface –X1
Interface for connecting the cables of the geared motor.
Harting Han Q8/0 socket
Contact
Allocation
1
Phase U
2
n.c.
3
Phase W
4
Motor holding brake
5
Motor temperature monitoring
6
Motor holding brake
7
Phase V
8
Motor temperature monitoring
9
PE