IV351 Rev04
Date Issue 2015-04-21
Page 121 di 277 + FR
6.
Operation of PV inverter
6.1 DC Switch Usage
The PV inverter starts up automatically once the DC-power from PV Panel is sufficient and
fuse is closed. However, if a DC switch is integrated at underside of the device, user has also
to switch it on in order to feed power to the device.
Attention:
The Inverter LCD screen will illuminate up at 260V
DC
, in order to feed power to
the grid constantly, DC input voltage must be greater than system initial feed-in
voltage 350V
DC
, see
Section 12.2.
6.2 Initialization for Regulation Type Setting
9
The Inverter provides a “Select Safety” function at the first time start-up as a process in
which user is able to select the intended language displayed and regulation type before
starting normal operation.
9
The Inverter will not able to operate normally before regulation setting is completed
even though it is connected correctly at both DC input and AC output.
9
The following flowchart illustrates the process of “Select Safety”. For example, if users
in German need to set regulatory type to VDE0126-1-1/A1, user has to power on the
Inverter start “Select Safety” process. Firstly user has to scroll the menu to the intended
regulatory page by button control, then hold on to the “OK” button for 5 more seconds
until “Regulation Setting OK” message appeared, the regulatory setting is completed.
Please Select Safety
Unknown
źŸ
: Select Safety
OK: Press Over 5 sec.
Æ
Please Select Safety
VDE0126-1-1/A1
źŸ
: Select Safety
OK: Press Over 5 sec.
Æ
Содержание SOLEIL 3F-TL10K
Страница 89: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 89 di 277 FR 17 2 Diagramma efficienza ...
Страница 90: ...IV351 Rev04 Date Issue 2015 04 21 Pagina 90 di 277 FR ...
Страница 108: ...IV351 Rev04 Date Issue 2015 04 21 Page 108 di 277 FR Mounting Bracket Notes Diameter for the safety screw is at 10mm2 ...
Страница 129: ...IV351 Rev04 Date Issue 2015 04 21 Page 129 di 277 FR Illustration of Data Logger Display Sequence ...
Страница 180: ...IV351 Rev04 Date Issue 2015 04 21 Page 180 di 277 FR 17 2 Efficiency Chart ...
Страница 181: ...IV351 Rev04 Date Issue 2015 04 21 Page 181 di 277 FR ...
Страница 221: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 221 von 277 FR Funktionsschema des Datenloggers ...
Страница 251: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 251 von 277 FR ...
Страница 275: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 275 von 277 FR 17 2 Wirkungsgradkurve ...
Страница 276: ...IV351 Rev04 Ausstellungsdatum 2015 04 21 Seite 276 von 277 FR ...