Code
Error message
Error reaction
Possible reason
▶
The heartbeat bit was not
toggled in time.
E11
(0x10B)
Communication / bus system error
The motor is stopped immediately
and disabled.
▶
The communication line is
defect or disturbed.
▶
The control source failed.
▶
The heartbeat bit was not
toggled in time.
E12
(0x10C)
Mains 'Ready for operation' is
missing
The motor is stopped immediately
and disabled.
▶
At least one mains phase is
lost.
E17
(0x311)
FPGA power output stage shut‐
down
Motor is stopped immediately.
▶
Overload in power supply unit
E18
(0x312)
Error in spindle selection
Converter will not be switched on.
▶
X32 is not connected.
▶
No spindle selected by the
CNC.
E26
(0x31A)
Motor temperature too high
The motor is stopped immediately
and disabled.
▶
The motor became too hot.
▶
The motor is overloaded.
▶
The cooling is insufficient.
▶
The motor temperature sensor
is defect or disturbed.
E27
(0x31B)
Ambient temperature too high
The motor is stopped immediately
and disabled.
▶
The temperature in the switch
cabinet is too high.
▶
The
ventilation
of
the
frequency converter is insuffi‐
cient.
▶
The fan is defect.
E28
(0x31C)
Power output stage temperature
too high
The motor is stopped immediately
and disabled.
▶
The temperature in the switch
cabinet is too high.
▶
The output stage is over‐
loaded.
▶
The
ventilation
of
the
frequency converter is insuffi‐
cient.
▶
The fan is defect.
E29
(0x31D)
Motor load too high (Motor I²t)
The motor is stopped immediately
and disabled.
▶
The motor is overloaded.
▶
The motor was operated too
long above the rated current.
▶
The setting for the motor para‐
meters is wrong.
▶
The motor is defective.
E30
(0x31E)
Power output stage load too high
(I²t)
The motor is stopped immediately
and disabled.
▶
The frequency converter is
overloaded.
▶
The frequency converter was
operated too long above the
rated current.
▶
The power output of the
frequency converter is too
small for the application.
▶
The setting for the motor para‐
meters is wrong.
E33
(0x521)
Power supply load monitoring ->
mains voltage too high
The motor is disabled immediately.
The power supply is cut immedi‐
ately from the mains.
▶
The parameter setting of the
power supply is wrong.
▶
The mains voltage was too
high.
E34
(0x522)
Power supply load monitoring ->
mains voltage too low
The motor is disabled immediately.
The power supply is cut immedi‐
ately from the mains.
▶
The parameter setting of the
power supply is wrong.
▶
The mains voltage was too
low.
E35
(0x523)
Error in external power supply unit
The motor is disabled immediately.
▶
The external power supply did
not acknowledge “Ready for
W
Status Display and Error Messages
FC2 - Frequency converter 02192100xy
63
11
Содержание FC2
Страница 1: ...FC2 Frequency converter 02192100xy Hardware Description P TD 0000552 2 2019 08 26 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Страница 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Страница 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Страница 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Страница 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Страница 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Страница 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...