8.10.4
Motor Temperature Sensor (X31A/B)
The FC2 provides up to 12 inputs for motor protection (PTC/NTC). One individual input
is provided for every spindle. The inputs must be connected correspondingly.
The input motor protection (PTC/NTC) allows for example connection of PTC resistors
that are often used in three-phase motors for temperature monitoring. Connecting
pressure control devices and controllers for coolant or lubricant that are conceived as
switch contacts is also possible.
If the connected value is higher than the programmed value, the frequency converter
triggers a higher-ranking stop process. During this process the motor is decelerated
until the speed value is zero. An error message is saved and displayed. The error
message is acknowledged via the reset functions.
8.11
X32 – Inputs for Spindle Selection
15-pole female submin D connector
X32
Pin
I/O
Name
Meaning
1
I
SP1
Spindle 1
2
I
SP2
Spindle 2
3
I
SP3
Spindle 3
4
I
SP4
Spindle 4
5
I
SP5
Spindle 5
6
I
SP6
Spindle 6
7
I
SP7
Spindle 7
8
I
SP8
Spindle 8
9
I
SP9
Spindle 9
10
I
SP10
Spindle 10
11
I
SP11
Spindle 11
12
I
SP12
Spindle 12
13
O
+24V
14
I/O
GND
Ground
15
I/O
GND
Ground
Stud bolt flange: max. tightening torque = 0.7 Nm
The number and position of the running spindles is selected via the connector X32.
One specific input is assigned to every spindle for spindle selection. The frequency
converter calculates the value for current limitation on the basis of the number of
selected spindles.
Related topics
Connection example: "X32 – Inputs for Spindle Selection", page 55
Connectors
W
44
FC2 - Frequency converter 02192100xy
8
Содержание FC2
Страница 1: ...FC2 Frequency converter 02192100xy Hardware Description P TD 0000552 2 2019 08 26 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Страница 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Страница 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Страница 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Страница 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Страница 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Страница 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...