6-pole Mini-Combicon connector, suitable for mating connector MC 1,5/ 6-ST-3.81
(Phoenix)
Mating connector X10
Pin
I/O
Name
Meaning
1
I
SAFEA /
OSSD1
Enable of the safety circuit
2
–
GND
Reference potential
3
I
SAFEB /
OSSD2
Enable of the safety circuit
4
O
OUT3
Digital output 4
5
O
OUT4
Digital output 5
6
O
24 V
(1)
Logic voltage 18 to 28 volts (uncontrolled)
(1)
The 24 V output is not suited to supply external safety circuits because an external voltage source is
necessary to comply with the applicable standards. If the safety function (STO) is not required, this voltage is
only used to bridge the pins 1 and 3.
Specification of terminal connections
▶
Conductor cross-section solid/stranded: 0.14 to 1.5 mm²
▶
Tightening torque: 0.22 to 0.25 Nm
The power supply unit is only activated when SAFEA and SAFEB are
connected. If the safety function (STO) is not required, pin 1 and pin 3 must
be bridged to pin 6.
Related topics
Connection example: "X10 – Safety Circuit (STO)", page 50
Safety function STO: "Safety Circuit / Restart Lock (STO)", page 65
8.6
X14 – USB
Communication interface to the connected PC
4-pole female USB connector, type B
X14
Pin
I/O
Name
Description
1
-
VCC
5 V voltage supply for USB
2
I/O
DN
Data−
3
I/O
DP
Data+
4
I/O
GND
Ground
8.7
X26/ X27 – SERVOLINK 4
SERVOLINK 4: optical input (X26) and optical output (X27)
The fiber optic connectors for SERVOLINK 4 are located at the bottom side of the
device.
Connectors
W
34
FC2 - Frequency converter 02192100xy
8
Содержание FC2
Страница 1: ...FC2 Frequency converter 02192100xy Hardware Description P TD 0000552 2 2019 08 26 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Страница 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Страница 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Страница 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Страница 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Страница 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Страница 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...