Code
Error message
Error reaction
Possible reason
The power supply is cut immedi‐
ately from the mains.
operation”. (Connector X1,
pins 1 and 2)
E37
(0x525)
Ballast circuit load (I²t ballast
resistor)
The motor is disabled immediately.
▶
The programmed delay time is
too short.
▶
The ballast circuit in the
frequency converter was over‐
loaded.
E42
(0x52A)
Overvoltage in DC link
The motor is disabled immediately.
▶
The programmed delay time is
too short.
▶
An overvoltage occurred in the
controlled DC link.
E45
(0x52D)
Short circuit in power output stage
The motor is disabled immediately.
▶
Short circuit of the output
wiring (motor cable/ motor).
▶
Short to ground of the output
wiring (motor cable / motor).
E46-1
(0x52E)
Safety circuit (Safety X10)
The motor is disabled immediately.
▶
The wiring of the connector
X10 is not correct.
▶
The external safety circuit has
triggered.
▶
The safety circuit / restart lock
has triggered.
E47
(0x52F)
Drive parameters not activated
The motor can not be turned on.
▶
Drive start is not acknowledged
by master yet.
E55
(0x737)
Firmware stopped by ESC
The drive does not start.
▶
Starting the firmware was
canceled by pressing ESC.
E56
(0x738)
Device configuration
The motor can not be turned on.
▶
During boot-up the device
detected that hardware, para‐
meters, firmware and logic are
not consistent. a detailed error
description is received by a
parameter download.
E57
(0x739)
Faulty or no firmware
The motor can not be turned on.
▶
During boot-up the device
detected no firmware or a
faulty firmware.
E58
(0x73A)
FPGA watchdog triggered
The motor is immediately disabled
or the drive does not start.
▶
FPGA process monitoring has
been triggered; please contact
SIEB & MEYER.
E59
(0x73B)
No drive parameters loaded
The motor can not be turned on.
▶
The parameter file is not
loaded.
E60
(0x73C
Drive parameters incorrect
The motor can not be turned on.
▶
The EEPROM is defective.
▶
Failure during data loading.
▶
The check sum of the para‐
meter memory is not correct.
E61
(0x73D)
Logic coding missing or incorrect
The motor can not be turned on.
▶
Logic programming of the
device is not valid.
E62
(0x73E)
Error in electronic type plate
The motor can not be turned on.
▶
Type plate is not programmed
or faulty; please contact
SIEB & MEYER.
Status Display and Error Messages
W
64
FC2 - Frequency converter 02192100xy
11
Содержание FC2
Страница 1: ...FC2 Frequency converter 02192100xy Hardware Description P TD 0000552 2 2019 08 26 SIEB MEYER W ...
Страница 4: ...Chapter Overview W 4 FC2 Frequency converter 02192100xy ...
Страница 8: ...Content W 8 FC2 Frequency converter 02192100xy ...
Страница 12: ...General Information W 12 FC2 Frequency converter 02192100xy 2 ...
Страница 22: ...Unit Assembly Complying EMC W 22 FC2 Frequency converter 02192100xy 4 ...
Страница 30: ...Technical Data W 30 FC2 Frequency converter 02192100xy 7 ...
Страница 48: ...Connectors W 48 FC2 Frequency converter 02192100xy 8 ...
Страница 70: ...Safety Circuit Restart Lock STO W 70 FC2 Frequency converter 02192100xy 12 ...