17
SRV285 TC
1.0.3 - 2015
Technical wiring diagram ,SRV models
The S-link control system is powered by a dedicated power cable con-
nected to the system backbone as a normal spur cable.
The cable ends connect to battery pos. and battery neg. and the cable
shield connects to battery neg.
The battery pos. must be connected through a 5A fuse.
NO
EN
S-link systemeter strømforsynt via en dediker strømkabel som kobles til
systemets “backbone” som en normal “spur”-kabel.
Kabelendene kobles til batteriets pluss- og minuspol og skjermkabelen
kobles til batteriets minuspol.
Ledningen som kobles til batteriets plusspol må sikres med en 5A sikring.
S-link koblingsskjema
S-link system schematics
To control
panel(s)
see manual
C4
C3
A1
A2
SIDE-
POWER
M
48 VDC
-
+
12V
Bat.
bank 1
(24V)
-
+
12V
K2
K1
C
o
Electronic
motor interface
K1
K2
Di1
Di2
Fuse
10-15 A
3 x 1,5mm
2
3m + extendable
1
2
3
Re1
-
+
12V
Bat.
bank 2
(24V)
-
+
12V
C1
30
87
Re1
Re2
30
87
Di
7
Main
Fuse
Bat.switch
Re2
Di
8
C2
Main Fuse
D
i6
Soft-start
timer
Brown
Blue
Bl
ue
Violet
White
Red
16¤
Bat.switch
Overtemp
Switch
Red
Grey
Black
Red
+
To engine starter,
alternator etc.
-
To engine starter, alternator
etc.
30
87
b
Re1
C1
D
i3
c1
C2
a
NOTES !
- Main battery fuses: recommended min. 325A
- Main battery switches : must be rated at
minimum 400A for minimum 10 minutes. Use
high quality switches to avoid voltage drop.
- See installation manual for correct cable sizes
for different total cable lengths
Black
Red
G
re
y
Bl
ue
White
NB!
A
1
Engine alternator
and or other
charge device 24V
+
-
Control lead
to box
PS ! Battery bank 2 can not be
connected to anything else.
Must be exactly as shown here.
*
*
*
*
*
Size of power cables
between batteries, box and
thruster is depending on
distance. Minimum is 50mm
2
Use minimum the main cable
sizes for main stretch as
adviced in the list in the
manual
*
Ba
tte
ry
ban
k
1
24
V
+
-
+
-
Ba
tte
ry
ban
k
2
24
V
+
-
+
-
Black
Grey
Red
Red
lBue
Red
Grey
Retract
Controller
150000
A1
+
D2
D1
A2
C
M
M
B+
B
grey
blue
white
Actuators
red
black
red
black
red
blue
Position sensor
Motor
AUX Battery
Bank 24V
red
pink
To S-link
control system
+
-
8
1
1
6
1
2
+
-
Dedicated Voltage
Doubler Battery Bank 24V
Red
Black
Grey
SERIES/
PARALLEL BOX
20124SRV
Retract
Controller
150000
A1
+
D2
D1
A2
C
M
M
B+
B
grey
blue
white
Actuators
red
black
red
black
red
blue
Position sensor
Motor
AUX Battery Bank 24V
red
pink
To S-link
control system
8
1
1
6
1
2
Dedicated Voltage Doubler
Battery Bank 24V
Red
Black
Grey
SERIES/
PARALLEL BOX
20124SRV
+
-
+
-
+
-
+
-