Telegram
type
Command
Binary
02 02 02 02 00 00 00 11 73 45 4E 20 4C 4D 44 73 63 61 6E 64 61 74 61
20 01 33
Activating the output of the measured values in SOPAS on a trial basis:
1.
Start the terminal emulator with the button.
2.
Select the Connect... command in the Connections menu in the dialog window and
establish communication with the TiM over the Ethernet or USB interface.
3.
Enter one of the two telegrams in the "Send telegram" input line as they appear
(automatically framed by STX and ETX when sending in the default setting). Pay
attention to blank characters in the string.
4.
Use the button to transmit the telegram to the device.
✓
The device responds by providing the data as a one-off or continuously in the dis‐
play area of the terminal emulator.
7
OPERATION
42
O P E R A T I N G I N S T R U C T I O N S | TiM781
8024231//2019-03-29 | SICK
Subject to change without notice