Field set
Switching inputs
Field shape
Default size of field 1
IN 1
IN 2
IN 3
IN 4
2
1
0
0
0
Rectangle, segmented L: 1.25 m, W: 2 m
3
0
1
0
0
Rectangle, segmented L: 1.5 m, W: 2 m
4
1
1
0
0
Rectangle, segmented L: 1.75 m, W: 2 m
5
0
0
1
0
Rectangle, segmented L: 1 m, W: 2 m
6
1
0
1
0
Rectangle, segmented L: 1.25 m, W: 2 m
7
0
1
1
0
Rectangle, segmented L: 1.5 m, W: 2 m
8
1
1
1
0
Rectangle, segmented L: 1.75 m, W: 2 m
9
0
0
0
1
Rectangle, segmented L: 1 m, W: 2 m
10
1
0
0
1
Rectangle, segmented L: 1.25 m, W: 2 m
11
0
1
0
1
Rectangle, segmented L: 1.5 m, W: 2 m
12
1
1
0
1
Rectangle, segmented L: 1.75 m, W: 2 m
13
0
0
1
1
Rectangle, segmented L: 1 m, W: 2 m
14
1
0
1
1
Rectangle, segmented L: 1.25 m, W: 2 m
15
0
1
1
1
Rectangle, segmented L: 1.5 m, W: 2 m
16
1
1
1
1
Rectangle, segmented L: 1.75 m, W: 2 m
Output form (rectangle), can be changed as desired, L = length, W = width
Input level: Low (in resting position): ≤ 2 V, high (in working position): ≥ 8 V
7.2.2
Monitor - field evaluation monitor
Figure 22: Device window: Monitor - field evaluation monitor
In the Field evaluation monitor window, SOPAS displays the field contour (scan line) cur‐
rently seen by the device through ambient reflection in blue.
If the 4 switching inputs are not supplied with current, SOPAS also displays the three
fields (segmented rectangles) for the field set 1 according to the device default setting,
or the field shape generated using the teach-in function along with its dimensions, the
status of the switching inputs/outputs, and the position of the mouse pointer.
OPERATION
7
8024231//2019-03-29 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM781
37
Subject to change without notice