Configuration
Configuration of the safety controller
The safety controller is configured by means of a rotary switch on the main module.
For further information on configuration and start sequence,
Classic safety controller", page 41
and see operating instructions for the Flexi Classic
safety controller.
Configuring the safety laser scanners
Depending on model, the safety laser scanners are configured using the Safety
Designer software or the CDS (Configuration & Diagnostic Software). For further infor‐
mation on configuration,
see "Configuring the safety laser scanner", page 42
operating instructions of the respective safety laser scanner.
Safety laser scanner
Configuration software
S300 Mini Standard
CDS (Configuration & Diagnostic Software)
microScan3 Core I/O
Safety Designer
S3000 Standard
CDS (Configuration & Diagnostic Software)
7.1
Requirements for software and firmware
Configuration of the safety laser scanner in this safety system requires at least the fol‐
lowing versions of the software or firmware:
Table 20: Minimum versions
Software and firmware
Minimum version
Safety Designer
1.2
CDS (Configuration & Diagnostic Software)
3.7.2
The software can be downloaded at
7.2
Additional configuration required
7.2.1
Configuring the Flexi Classic safety controller
The Flexi Classic safety controller is configured by means of a rotary switch. A screw‐
driver is required for this.
CAUTION
If a change is made to the configuration, the protective device must be checked to
ensure that it is effective. For this purpose, the test instructions in the operating instruc‐
tions of the respective component must be observed.
1.
Switch off the voltage supply at all main modules (terminals A1 and A2).
2.
Using a screwdriver, set the desired switch settings (programs and functions) at
the rotary switches on all modules.
3.
Set the control functions through external wiring of terminals S1, S2 and S3 on all
modules.
4.
Switch on the voltage supply of all modules while pressing the Enter pushbutton of
the main module.
NOTICE
Do not press any of the connected reset pushbuttons when doing this.