3
SYSTEM DESCRIPTION
30
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
3.3.4
Measurement site for TIC501
The mounting position of the TIC501 can be adapted flexibly to the local conditions.
It is supported analog to the TIC102 / TIC502 via overhead mounting on a gantry.
The beam of the TIC501 is emitted perpendicular to the road surface.
Several lanes can be monitored with one TIC501. A maximum of four lanes can be
monitored with a TIC501 if mounted in the center.
Fig. 17: Measurement site – TIC501 overhead mounting (monitoring of 2 lanes)
A TIC501 can be expanded with up to three additional LMS511 units. Several roads can
be monitored at the same time in this way.
Fig. 18: Measurement site – TIC501 (monitoring of 3 + 3 lanes)
Side mounting above the lane on a post or mast is also possible. A maximum of two lanes
can be monitored with a TIC501 if mounted on the side.
Fig. 19: Measurement site – TIC501 side mounting (monitoring of 2 lanes)