6
COMMISSIONING
114
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
5. Click
Assign Device
. The sensor is assigned to the
LMS Width
system component.
In the list of devices, the 2D LiDAR sensor now appears with a green background.
The green background color indicates that the assigned device belongs to the current
component. The devices yet to be assigned are still blue.
Accidentally assigning the LMS Width to an LMS Length is prevented by the system.
6. Once the change has been made, click
Close
.
The device search closes. The red circle containing the error number has now
disappeared from both
LMS Width
listings.
7. Apply the same process when assigning devices for the two 2D LiDAR sensors to the
LMS Length
system components. Start again with the system component of the
TIC102 Slave 2
system function.
All red error numbers must have disappeared by the end.
Note