Wiring CAN interfaces via a connection module
Connection modules
Interface
Reference
CDB650-204
CAN
see "Wiring the CAN interface of
the device in the CDB650-204",
page 59
CDM420-0006
CAN
see "Wiring the CAN interface of
the device in the CDM420-0006",
page 69
6.5.4
Connecting the supply voltage
The voltage source meets the requirements of ES1 and PS2 (EN 62368-1) or SELV and
LPS (EN 60950-1).
Table 7: Required supply voltage V
S
and power output
Supply voltage V
S
Power source: required power output
1)
DC 12 V ... 24 V ± 20%
Maximum 30 W
1)
Valid for device with 4 loaded digital outputs (each 100 mA).
When connecting via the optional CDB or CDM connection module: if the CMC600
cloning module is used, an additional output power of 0.5 W is required.
Table 8: Typical current consumption depending on supply voltage
Designation
Supply voltage (V
S
) in [DC V]
9.6
(12 V -20%)
12
24
28.8
(24 V +20%)
Maximum supply current
(2 A fuse)
I
RMS max
1)
[A]
1.5
1.5
1.5
1.5
Current consumption: device
Current consumption, dig‐
ital outputs unloaded,
standby
I
B RMS
[A]
0.58
0.47
0.24
0.21
Current consumption, digi‐
tal outputs unloaded, inte‐
grated illumination unit off
I
B RMS
[A]
0.86
0.68
0.35
0.30
Maximum current con‐
sumption, digital outputs
unloaded, integrated illumi‐
nation unit on
I
B peak
2)
[A]
1.09
0.90
0.45
0.36
Typical, all 4 digital outputs
loaded (0.1 A per output)
I
B RMS 4Out
[A]
1.26
1.08
0.75
0.70
Power loss, integrated illu‐
mination unit on
P
RMS
[W]
8.3
8.2
8.4
8.7
Maximum current consumption: external lighting via connection for external illumination unit
on the device
3)
Current consumption, digi‐
tal outputs unloaded
I
B RMS max
[A] 0.64
0.65
0.65
0.65
All 4 digital outputs loaded
(0.1 A per output)
I
B RMS max 4
OUT
[A]
0.24
0.42
0.65
0.65
1)
Valid for supply cable rating and fuse at the start of the cable.
2)
Valid for power supply unit rating.
3)
Illumination units with a higher current consumption are possible, but the peak currents may be signifi‐
cantly higher. Limit output current internally to 0.65 A RMS by a cold conductor (PTC).
6
ELECTRICAL INSTALLATION
40
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
8019946/1EJ6/2022-02 | SICK
Subject to change without notice