Type
InspectorP63x Flex (V2D6xxP-Mxxxxx)
Image recording rate
•
1.3 Mpx: 50 Hz
•
1.9 Mpx: 50 Hz
Ambient light tolerance
2.000 lx on surface
Image memory
Image and data logging on microSD memory card (max. 32 GB),
internal RAM (512 MB) and external FTP
11.3
Interfaces
Type
InspectorP63x Flex (V2D6xxP-Mxxxxx)
Serial
RS-232/ 422
Host (300 Bd ... 115.2 kBd), for data output
Serial RS-232
AUX (57.6 kBd)
USB
Not supported
Ethernet
Image transmission (FTP). 10/100/1,000 MBit/s, TCP/IP, PROFI‐
NET IO, EtherNet/IP
1
. MAC address(es), see type label.
CAN
20 kbit/s ... 1 Mbit/s
Protocol: SICK CAN sensor network
PROFIBUS
1
Optional via external fieldbus module CDF600-21xx
PROFINET IO
Built-in, additionally available (optional) via external fieldbus mod‐
ule CDF600-2200
Digital switching inputs and
outputs
2 x Sensor 1 and 2
4 x physical (freely configurable inputs and outputs)
2 x additional external via optional CMC600
1
module in connec‐
tion module CDB650-204 or CDM420-0006 (external input/out‐
put 1 and 2)
Digital switching inputs
2 x Sensor 1 and 2
4 x physical (configurable IN 3 ... 6)
U
e
= max. 32 V, I
e
= max. 5 mA, opto-decoupled, reverse polarity
protected, adjustable debounce time
Digital switching outputs
4 x physical (configurable OUT 3 ... 6)
0 V
≤
U
a
≤
U
V
(U
V
- 1.5 V)
≤
U
a
≤
U
V
at I
a
≤
100 mA. Short-circuit protected,
temperature protected. Not galvanically isolated from the supply
voltage.
1
Function planned
11.4
Mechanics and electronics
Type
InspectorP63x Flex (V2D6xxP-Mxxxxx)
Optical indicators
5 x RGB LEDs: status indicators
1 x LED: feedback LED, green/red
5 x RGB LEDs: bar graph, blue
Acoustic indicators
1 x beeper for signaling events, can be deactivated
External backup of configu‐
ration data
Optional on plug-in micro SD memory card or via optional CMC600
module in connection module CDB650-204 or CDM420-0006.
Supply voltage
DC 10 V … DC 30 V,
SELV (DIN EN 60950-1:2014-08),
LPS (DIN EN 60950-1:2014-08) or Class 2 (UL 1310)
Current consumption
Max. 1.5 A (with switching outputs)
Power consumption
10 W (for unloaded switching outputs)
TECHNICAL DATA
11
8019946/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
51
Subject to change without notice