6.5.6
Wiring the digital outputs
The four IN/OUT 3 ... 6 switching digital outputs can be assigned independently of each
other with various functions for the output of the result status. If the allocated event
occurs in the analysis process, then the corresponding digital output is live after the
end of the trigger for the selected pulse duration.
Position of digital outputs
•
Male connector of the device (M12, 17-pin, A-coded)
•
Open end of the adapter cable (female connector, M12, 17-pin, A-coded/open
end)
•
CDB650-204 connection module
All digital outputs are each available at the individual positions.
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
b
Attach a freewheeling diode directly to the load for this purpose.
NOTE
Capacitive loads on the digital outputs have an effect on the switch-on and switch-off
behavior. A maximum capacitance of 100 nF is the limit value.
Function assignment
NOTE
Control the digital outputs in the device with the API functions. In order to assign the
digital output functions, use an installed SensorApp which contains this function.
Wiring digital outputs via connection module
Connection mod‐
ules
Digital outputs
Reference
CDB650-204
IN/OUT 3 ... 6 (RES/OUT 1 ... 4)
see "Wiring digital outputs of
the device in the CDB650-204",
page 63
CDM420-0006
N/OUT 3 ... 4
see "Wiring digital outputs of
the device in the CDM420-0006",
page 73