CAUTION
Warning! Optical radiation: LED risk group 2, visible radiation, 400 nm to 780 nm
Potentially dangerous optical radiation. Can be damaging to the eyes.
■
Do not look into the light source for extended periods of time.
■
Never point the light source at people.
■
Avoid any reflections on people from reflective surfaces. Be particularly careful
during mounting and alignment work.
■
Do not open the housing. Opening the housing will not switch off the light source.
Opening the housing may increase the level of risk.
■
Comply with the current national regulations on photobiological security of lamps
and lamp systems.
If the product is operated in conjunction with external illumination systems, the risks
described here may be exceeded. This must be taken into consideration by users on a
case-by-case basis.
CAUTION
Optical radiation: Class 1 Laser Product
The accessible radiation does not pose a danger when viewed directly for up to 100
seconds. It may pose a danger to the eyes and skin in the event of incorrect use.
■
Do not open the housing. Opening the housing may increase the level of risk.
■
Current national regulations regarding laser protection must be observed.
For both radiation types:
It is not possible to entirely rule out temporary disorienting optical effects, particularly
in conditions of dim lighting. Disorienting optical effects may come in the form of
dazzle, flash blindness, afterimages, photosensitive epilepsy, or impairment of color
vision, for example.
b
Switch off the device for the duration of the cleaning operation. If this is not
possible, wear suitable laser safety goggles. These must absorb radiation of the
device’s wavelength effectively.
b
Glass window: remove dust from the viewing window using a soft, clean brush. If
necessary, also clean the viewing window with a clean, damp, lint-free cloth, and a
mild anti-static lens cleaning fluid.
b
Plastic window: clean the viewing window only with a clean, damp, lint-free cloth,
and a mild anti-static lens cleaning fluid.
NOTICE
If the inspection window is scratched or damaged (cracked or broken), the lens must be
replaced. Contact SICK Support to arrange this.
■
If the inspection window is cracked or broken, take the device out of operation
immediately for safety reasons and have it repaired by SICK.
8.3
Repairs
Repair work on the device may only be performed by qualified and authorized personnel
from SICK AG. Interruptions or modifications to the device by the customer will invalid‐
ate any warranty claims against SICK AG.