5.3.1.2
Assembling kit variants with C-mount lenses and external ICL ring lighting
1
2
3
4
5
6
7
1
Camera housing
2
C-mount filter (optional)
3
Spacer disk (included with delivery of filter)
4
C-mount lens
5
Mounting bracket for ICL ring lighting
6
Protective lens cover for ICL ring lighting
7
ICL ring lighting
1.
Place the camera housing on a nonslip base.
2.
Remove the protective cap from the round light inlet.
3.
Carefully insert the optional filter and spacer disk into the light inlet
4.
Screw the lens unit into the C-mount thread until it engages. This will also lock the
optional filter in place at the same time.
5.
Mount the mounting bracket to the side of the camera housing.
6.
If the required adjustments are not carried out immediately, mount the protective
optics cover.
7.
Mount the illumination unit and connect the cable to the connection box.
MOUNTING
5
8019946/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
23
Subject to change without notice