Function of switch S7
Table 12: Switch S7: Term 485
Switch setting
Function
ON
Terminates the RS-422 receiver in the device to improve the noise ratio
on the line
OFF
No termination
NOTE
User of the RS-422 data interface:
•
The relevant interface drivers for the device comply with the standard in accord‐
ance with RS-422.
•
The connection shown above is configured for operation of the host with perma‐
nently activated drivers (often described as “RS-422 operation”).
•
Activate the RS-422 data interface (“Point-to-Point” option) in the device with
SICK AppStudio.
13.3.6
Wiring the CAN interface of the device in the CDB650-204
Device = InspectorP63x = V2D63xP-xxxxBx
Not considered: connection and looping through of the supply voltage, connection of a
trigger sensor for read cycle generation (e.g. at the master)