4
Mounting
4.1
Mounting requirements
Important notes
NOTICE
Different operating conditions to the standard device apply for the device type
V2D621x-xxxxxx6x (cold storage applications). The operating conditions must be
adhered to at all times.
Information on the operating conditions is included in the addendum to operating
instructions for the “InspectorP621, Lector621: V2D621x-xxxxxx6x” (part number:
8027368,
Carefully read the supplement to operating instructions before using the device.
General mounting requirements
•
The working distance from the device to the positioning mark depends on the
device type and type of positioning mark.
•
The positioning mark can be positioned anywhere in the field of view of the device
to suit the application situation. Recommendation: Locate the positioning mark at
the center point of the image.
•
The positioning mark is located in the field of view for single-deep and double-
deep rack storage.
•
Multiple positioning marks within the field of view of the device can be classified
and ignored.
•
Orient the device perpendicular to the metal surface or positioning mark. Do not
angle the device relative to the surface.
•
Mount the device in a shock and vibration insulated manner. Ensure that the
position of the device is not moved by vibrations during operation.
Mounting requirements: hole as positioning mark
•
No objects or contamination with distinct contours, a similar diameter, or a similar
surface are present in the field of view.
•
Do not mount any light sources behind the hole.
•
The beams of the high-bay rack system are not heavily contaminated in the area of
the hole. If necessary, clean the area around the hole.
Mounting requirements: reflector as positioning mark
•
Do not mount any light sources in the field of view of the device.
•
The reflector is not contaminated. No reflections are possible. If necessary, clean
the reflector.
•
When fine positioning using reflectors, the device searches the image for bright
structures against a dark surrounding. Use a polarizing filter to prevent total reflec‐
tion of the illumination. The polarizing filter hides the total reflecting light from the
surface.
Complementary information
You can find the polarizing filter as an accessory on the Internet at
by
entering the part number in the search field.
Polarizing filter
•
InspectorP621P polarizing filter: part number 2088228
•
InspectorP631P polarizing filter, part number 2088229
MOUNTING
4
8024534/1DQ8/2022-01-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP Rack Fine Positioning
13