Operating Instructions
Symbology Reading Control
IDM corded & IDM Bluetooth
8017159/142O/2019-05-23
© SICK AG · Germany · All rights reserved · Subject to change without notice
51
3.7.6
Codabar/ NW-7
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
Codabar Settings
SS Disable Codabar
0
SS Enable Codabar
1
SS Select Codabar standard format
2
SS Select Codabar ABC format
3
SS Select Codabar CLSI format
4
SS Select Codabar CX format
5
SS Disable start/stop symbol transmission
6
SS Enable ABCD/ABCD start/stop symbol transmission
7
SS Enable abcd/abcd start/stop symbol transmission
8
SS Enable ABCD/TN*E start/stop symbol transmission
9
SS Enable abcd/tn*e start/stop symbol transmission
A
SS Disable check digit verification
B
SS Enable check digit verification
C
SS Disable check digit transmission
D
SS Enable check digit transmission
E
Codabar Check Digit
Settings
SS Modulus 16
0
SS Modulus 10/weight 3
1
SS Modulus 11
2
SS Modulus 10/weight 2
3
SS 7 check DR
4
SS Weight Modulus 11
5
SS Runes (Modulus 10/weight 2)
6
Codabar Min. Length
SS Default (04)
FIN
MS 01-98
(2 digits)
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
Codabar Max. Length
SS Default (98)
FIN
MS 01-98
(2 digits)