Operating Instructions
Serial Interface Control
IDM corded & IDM Bluetooth
8017159/142O/2019-05-23
© SICK AG · Germany · All rights reserved · Subject to change without notice
39
3.5
Serial Interface Control
3.5.1
Suffix, Preamble, Postamble
PROGRAM
F_DEFAULT
Family Code Selection
P.C.
Parameter Selection
Option Code
STX/ ETX Control
SS Disable STX/ETX transmission
0
SS Enable STX/ETX transmission
1
STX/ETX are two characters used to indicate the starting and
ending of the total data frame transmitted via serial
interface.
Record Suffix
SS None
0
SS CR (0DH)
1
SS LF (0AH)
2
SS CRLF (0D0AH)
3
SS TAB (09H)
4
SS SPACE (20H)
5
Preamble
SS None
FIN
MS 1-15 characters
[00-7F], FIN
Maximum 15-character input; scan “FIN” to terminate this
selection.
Postamble
SS None
FIN
MS 1-15 characters
[00-7F], FIN
Maximum 15-character input; scan “FIN” to terminate this
selection.
FNC1 Symbol Char.
Transmit
SS Disable
0
SS Enable
1
When this function is enabled and the FNC1 is contained in
scanned data, the scanner transmits the FNC1 to the host. A
chart of the FNC1 is provided in the GS1-128 ASCII Table.
When the scanner interface is set to keyboard, the scanned
code is converted to corresponding key function before it is
transmitted.
Serial Interface Message String (RS-232, USB COM)
STX
Preamble
Data
Length
Prefix
Symbol ID
Scanned
Data
Suffix
Symbol ID
Postamble
ETX
Record
Suffix
1
character
1-15
characters
2-4
digits
1 or 3
characters
Variable
length
1 or 3
characters
1-15
characters
1
character
1