background image

Bluetooth Operation Control (IDM Bluetooth 

series)

 

Operating Instructions 

 

IDM corded & IDM Bluetooth 

 

 

100

 

© SICK AG · Germany · All rights reserved · Subject to change without notice 

8017159/142O/2019-05-23

 

 

3.10.4

 

Bluetooth Device name, Security Settings 

 
 

 

 

 

 

PROGRAM 

 

 

F_DEFAULT 

 

 

 

 

Family Code Selection 

P.C. 

Parameter Selection 

Option Code 

Bluetooth Device Name 

 

SS  Default device name 

 

FIN 

MS  User defined 

IDM1xx: 1-16 characters 
IDM2xx: 1-32 characters  

[00-7F], FIN 

 

The default device name is: IDMxxx

 

 

Bluetooth PIN Code 

 

SS  Default Bluetooth PIN Code 

 

FIN 

MS  User defined (1-8 numbers) 

[30-39], FIN 

 

The default PIN code is: 00000000 

 

Bluetooth Authentication 

 

SS  Disable  

SS  Enable 

 

 

Bluetooth Authentication 

You can enable or disable the Bluetooth Authentication between the scanner and remote host device. If this 
function is enabled, when the scanner wants to connect itself and sends the data to the host device, the host 
device has to return a link key shared between the scanner and the host device. 

Содержание IDM series

Страница 1: ...O P E R A T I N G I N S T R U C T I O N S IDM Corded Bluetooth HAND HELD SCANNERS ...

Страница 2: ...Otherwise the configuration codes contained in this manual may be distorted and cannot be scanned anymore Regulatory EN61000 3 2 EN61000 3 31 EN60950 1 EN61000 6 3 EN61000 6 22 KN22 KN24 KN61000 2 3 4 5 6 8 11 3 Clause 2 Article 58 2 of Radio Waves Act4 Part 15B Part 15C4 V 3 2011 04 TECHNICAL REQUIREMENTS Class B ITE3 CNS13438 CNS14336 MIC T401 AS NZS CISPR 22 2009 Class B LED Eye Safety IEC62471...

Страница 3: ...2 3 Radio Link Mode 15 2 3 1 PAIR Mode 16 2 3 2 PICO Mode 16 2 3 3 HID Mode 18 2 3 4 SSP Master Slave Mode 20 2 4 Out of Range Scanning 21 2 5 Presentation Scanning 22 2 6 Battery status IDM Bluetooth only 22 2 7 Sleep Mode Power Off 22 2 8 Batch Scanning Inventory Mode 23 2 8 1 Quantity feature 23 2 8 2 Data output format 24 2 8 3 Transmit stored data 25 2 8 4 Delete data 25 3 Configuration via B...

Страница 4: ...pon Extended Code 57 3 7 10 IATA Interleaved 2 of 5 58 3 7 11 Code 25 Family 59 3 7 12 Code 11 Code 93 60 3 7 13 MSI Plessey 61 3 7 14 Code 128 62 3 7 15 GS1 128 64 3 7 16 UK Plessey 66 3 7 17 Telepen 67 3 7 18 GS1 DataBar 68 3 7 19 Composite Codes Codablock F PDF417 Micro PDF417 69 3 7 20 Code 16K Code 49 70 3 7 21 QR Code 71 3 7 22 Data Matrix 72 3 7 23 Aztec Code 73 3 7 24 Autralian Post US Pla...

Страница 5: ... Postamble Data Length Symbol ID Transmission 105 3 12 2 Data Formatter 106 3 12 3 Data Verifier 107 3 12 4 Data Replacer 108 3 12 5 Data Organizer 109 3 12 6 Select Barcode Symbology 110 3 12 7 Position Calculation 111 3 12 8 Application Example 111 4 IDM Set Up Tool 113 4 1 Configuration via IDM Set Up Tool 113 4 1 1 IDM Corded Scanners 113 4 1 2 IDM Bluetooth Scanners 113 4 2 Firmware Upgrade v...

Страница 6: ...different models for variant target applications IDMx2x and IDMx4x can be used for general purpose applications whereas IDMx6x is designed for industrial environments IDM Corded Scanners IDM120 IDM140 Operating indicator Status indicator Trigger Viewing window IDM160 IDM260 IDM240 Beeper Unlocking opening for connection plate Mounting eye metal Mounting eye plastic IDM Bluetooth Scanners IDM141 ID...

Страница 7: ...s reserved Subject to change without notice 7 IDM Bluetooth Cradles IDMx41 smart base station IDMx41 charging station Operating indicator Status Indicators Paging Reset pushbutton USB bus power switch IDMx61 smart base station IDMx61 charging station Host interface DC female connector power supply unit Reserved ...

Страница 8: ...s to be connected to the smart cradles The cable inlet is on the bottom side of the cradles IDMx41 base cradle IDMx61 base cradle Correct Not correct Ensure that the cable is pushed all the way into the RJ inlet of the base cradle to secure the data transmission to the host 1 1 1 Standard Interfaces RS 232 USB IDM scanners support USB1 and RS 232 Serial interfaces USB HID Human Interface Device Th...

Страница 9: ...y needed for operation with RS 232 cables1 Bluetooth 6036722 1 1 2 Industrial fieldbus The IDM Hand held scanners can be connected to industrial fieldbuses such as PROFIBUS PROFINET Ethernet TCP IP DeviceNet etc via SICK connection modules and an adapter cable The adapter cable includes a voltage converter from DC 24 to 5 V for the voltage supply of the hand held scanner eliminating the need of a ...

Страница 10: ...FINET PROFIBUS DeviceNet 3 Optical indicators 1 LED good read 2 LEDs operational status good read Vibration No No Yes No Yes Acoustic indicators Beeper disengageable Operating Voltage 5 V DC 5 Current consumption Operating Typical 170 mA Typical 180 mA 180 mA Vibrator disabled 230 mA Vibrator enable Typical 395 mA Max 395 mA Vibrator disabled Max 420 mA Vibrator enable Current consumption Standby ...

Страница 11: ...ion of the wireless radius Up to 100 m free view Batch function for expansion of the wireless radius Optical indicators 2 LEDs good read charge of battery radio connection status Vibration No Yes No Yes Acoustic indicators Beeper disengageable Operating Voltage 5 V DC 5 Current consumption Operating 180 mA 230 mA Vibrator enabled 180 mA Vibrator disabled 750 mA charging incl base station 750 mA ch...

Страница 12: ...an use the overlapping battery label to pull out the battery if needed 2 1 2 Charging the battery 1 Choose an appropriate plug for your country and slide it into the power adapter cavity until it is locked Then plug the AC power plug into the AC wall socket 2 Please make sure the USB bus power switch is in OFF position 3 Plug the DC power cord of the power supply unit into the DC Jack of the cradl...

Страница 13: ... is available in your host device the external power supply is necessary as a power source because the power supplied from USB 2 0 is not enough to support both battery charging and regular operation simultaneously Important information Please charge the new battery pack for 8 hours prior to the first use Ensure that you are using a battery with enough capacity Otherwise the scanner might lose its...

Страница 14: ...g tone Data Transmission Quick blue blink Short clicks Description Status Indicator Beeper Under charging on cradle Steady red Off Fully charged on cradle Steady green Off Under batch scanning 1 green blink per 2 5 sec Off Pair failure Steady red 2 Di do Di do beeps Out of memory 2 red blinks 2 long beeps Battery power low 1 red blink at regular interval 1 beep at regular interval Battery power ex...

Страница 15: ... paging function helps to locate the paired smart cradle or scanner If you would like to page the paired smart cradle you can scan the Paging command Paging If you would like to page the paired scanner you can press the paging rest button of the smart cradle no longer than 5 seconds 2 3 Radio Link Mode The IDM Bluetooth scanners provide several radio link modes to communicate with the host device ...

Страница 16: ... cradle 5 Scan the PAIR mode command The status indicator of the scanner will turn steady red immediately Uninstall PAIR Mode Place the scanner into the smart cradle You will hear one short beep to indicate the activation of the pairing process The scanner will emit continuous short clicks and the link indicator of the scanner will flash blue quickly during the pairing process When you hear 4 beep...

Страница 17: ...ntinuous short clicks and the link indicator of the scanner will flash blue quickly during the pairing process When you hear 4 beeps in ascending tone the pairing process is completed You will see that the link indicator of the scanner shows 1 blue blink per 2 5 seconds The central IDMx41 upper IDMx61 power indicator of the smart cradle turns steady blue and the side IDMx41 lower IDMx61 status ind...

Страница 18: ...terface Control Keyboard Layout Intermessage Delay Interfunction Delay Intercharacter Delay Caps Lock Control Caps Lock Release Control Function Key Emulation Key Pad Emulation Upper Lower Case Serial Interface Control Handshaking Protocol Intermessage Delay Interfunction Delay Intercharacter Delay Baud Rate Data Frame Time Out Control Wand Emulation Control Output Polarity Initial Signal State Ma...

Страница 19: ...you use HID Mode with Passkey you will be requested to enter the passkey PIN on the remote host Please enter the passkey PIN accordingly by scanning the Option Codes on page 132 and then scan FIN Finish to end the passkey entry Continue with step 9 8 If you scan HID Legacy Mode the passkey PIN may be requested Please enter 00000000 default setting You will see Keyboard on IDMxxx Double click this ...

Страница 20: ...s indicator of the scanner gives alternative red and green blinks Uninstall state If the scanner is not in uninstall state please scan the Uninstall command first and then scan the SPP Master Mode command The status indicator of the scanner will turn steady red immediately Uninstall SSP Master Mode 4 Scan a 12 character MAC address barcode or scan 12 option codes and FIN command to confirm your in...

Страница 21: ...anner and remote host device 5 The scanner will emit 4 beeps in ascending tone to indicate the radio is connected At the same time the link indicator of the scanner will give 1 blue blink per 2 5 seconds to indicate the scanner is in radio connected state Please note that if the scanner is not connected to the host device within 1 minute after scanning the SPP Slave Mode command the scanner will g...

Страница 22: ...art Cradle Presentation scanning on cradle is only available for IDMx41 series Disable Auto sense Enable Auto sense 2 6 Battery status IDM Bluetooth only You can check battery status of the scanner by short pressing the Left Key or scanning Check Battery Status command Check Battery Status Available Firmware IDM141 3 IDM161 3 4 00 05 and above IDM241 1 IDM261 1 2 00 03 and above IDM241 3 IDM261 3 ...

Страница 23: ...d into the memory storage and the status indicator of scanner will give green blink at regular interval during batch scanning You can scan and store the barcode data till the memory storage is full If the storage is full you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage To terminate the batch scanning please scan the Exit Batch Scanning command E...

Страница 24: ...ion The preset output format is to transmit stored data as many times as the quantity indicates But you still can set the scanner to output stored barcode data together with quantity information in two fields and a preset delimiter will be output in between To fulfill different application requirements both the delimiter and the output sequence can be changed As many times as the quantity indicate...

Страница 25: ...nsmit stored data You are still able to set the scanner to transmit the stored data by placing the scanner onto the cradle as well Scan Barcode Command Place scanner onto the cradle Scan command or place scanner onto the cradle 2 8 4 Delete data If a wrong barcode was scanned the Delete Last Scanned Data command is helpful to recover mistakes By scanning the Delete Last Scanned Data command the la...

Страница 26: ... programming family IDM Scanner has already provided more than one hundred programming families to meet any specific requirements 3 1 3 Option Code The Option Codes is a set of bar code commands represented by 0 9 A F and finishing selection FIN For most setting you must select at least one option code following the family code selection to set the desired parameter for the selected programming fa...

Страница 27: ...ramming category SS Single scan selection MS Multiple scan selection CS Cycling scan selection DS Dual level scan selection Necessary option code Selectable option code 3 2 1 Program End Please note that the IDM Scanner will take 3 4 seconds to store parameters in internal Flash Memory ASIC or non volatile memory after you scan the END Please don t turn off the power before the completion beeping ...

Страница 28: ...factory preset configurations and then issue the completion beeping The scanner will list the product information and revision number to host via selected host interface then issue the completion beeping Scan SYSLIST Scan one of family codes Scan PROGRAM Scan one of option codes Repeat selection Scan END Yes No Enter Programming mode Select the desired programming family Select one option code for...

Страница 29: ...ultiple Scan Scan one of family codes Scan PROGRAM Scan one or several option codes Repeat selection Scan END Yes No Enter Programming mode Select the desired programming family Select one or several option codes for the desired parameters If it s necessary scan FIN to terminate the option code selection Do you want to select another programming family Exit programming mode ...

Страница 30: ...an Scan one of family codes Scan PROGRAM Scan one or several option codes Repeat selection Scan END Yes No Enter Programming mode Select the desired programming family Select one or several option codes for the desired parameters as Single or Multiple scan selection Do you want to select another programming family Exit programming mode Scan FIN Finish cycling selection If necessary ...

Страница 31: ...RAM 1 st Scan several option codes Repeat selection Scan END Yes No Enter Programming mode Select the desired programming family Select several option codes for the desired parameters 1 Select one or several option codes for the desired parameters 2 If it s necessary scan FIN to terminate the option code selection Do you want to select another programming family Exit programming mode 2 nd Scan one...

Страница 32: ...nterface Selection MS IBM PS 2 25 30 series keyboard wedge interface 02 MS Standard TTL RS 232 peer to peer serial 06 MS Wand Emulation 08 MS USB Com Port Emulation 09 MS PS 2 DOS V direct link keyboard replacement 10 MS PS 2 DOS V keyboard wedge turbo mode 13 MS PS 2 DOS V keyboard wedge standard mode 14 MS Laser emulation 17 MS USB HID standard mode 18 MS USB HID turbo mode 19 MS USB HID Legacy ...

Страница 33: ...way QWERTY 08 SS Spain Latin America QWERTY 09 SS Italy QWERTY 10 SS Netherlands QWERTY 11 SS Denmark QWERTY 12 SS Belgium AZERTY 13 SS Switzerland Germany QWERTZ 14 SS Iceland QWERTY 15 SS Japan DOS V 16 SS Czech QWERTY 17 Please refer to the ASCII HEX Table listed in the Appendix to determine the HEX codes for characters symbols and functions to be used as preamble or postamble To set preamble o...

Страница 34: ...n FIN to terminate this selection FNC1 Symbol Char Transmit SS Disable 0 SS Enable 1 Caps Lock Control SS Caps Lock Off State 0 SS Caps Lock On State 1 SS Auto Detect PC AT PS 2 Keyboard Replacement and DOS V Machines only 2 Caps Lock Release Control SS Caps Lock On Caps Off 0 SS Caps Lock On Shift Off 1 FNC1 Symbol Character Transmit When this function is enabled and the FNC1 is contained in the ...

Страница 35: ...ix then the scanner will terminate this selection automatically Interfunction Delay SS None FIN MS 01 99 x5 msec 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Intermessage Delay is a time delay between messages outputted by the Hand held scanner Increasing this delay will help host applications to process the incoming...

Страница 36: ...y pad Num Lock On output 1 Upper Lower Case SS Normal case neglect the upper lower case control 0 SS Inverse case change all characters output to inverse case 1 SS Upper case force all characters output as upper case 2 SS Lower case force all characters output as lower case 3 Dollar Sign Control SS Dollar sign output as 0 SS Dollar sign output as 1 SS Dollar sign output as 2 SS Dollar sign output ...

Страница 37: ... Latin 5 Turkish 26 MS ISO 8859 10 Latin 6 Nordic 27 MS ISO 8859 11 Thai 28 MS ISO 8859 13 Latin 7 Baltic 29 MS ISO 8859 14 Latin 8 Celtic 2a MS ISO 8859 15 Latin 9 2b MS ISO 8859 16 Latin 10 South Eastern European 2c Keyboard Output MS MAC Unicode Output 01 MS WIN Notepad Unicode Output 02 MS WIN Wordpad Unicode 03 MS Output Code page 950 Output 10 MS Code page 949 Output 11 MS Code page 936 Outp...

Страница 38: ...display the content of a2D barcode select the code page that corresponds to the content s language Please check your system locale setting in Windows and make sure that it also matches this language 1 Mac Device Output If your host is a Mac device select MAC Unicode Output as the scanner s output setting the data will be in Unicode You must also first ensure that your Mac device has the required U...

Страница 39: ...5 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Postamble SS None FIN MS 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection FNC1 Symbol Char Transmit SS Disable 0 SS Enable 1 When this function is enabled and the FNC1 is contained in scanned data the scanner transmits the FNC1 to the host A chart of the FNC1 is provided ...

Страница 40: ...inate this selection automatically Intermessage Delay is a time delay between messages outputted by the Hand held scanner Increasing this delay will help host applications to process the incoming data on time Intercharacter Delay is a time delay between data characters outputted by the Hand held scanner These two parameters are used to synchronize data communication when 1 the data transmission sp...

Страница 41: ...he host computer after each data transmission If the NAK is received the Hand held scanner will re send the data until receiving ACK This function is not available for IDM Bluetooth Scanners in PICO or HID Mode NAK Retry Count After transmitting data the scanner expects a NAK response from the host up to the preset Serial Response Time out If the scanner doesn t get a response the scanner will iss...

Страница 42: ...AULT Family Code Selection P C Parameter Selection Option Code Serial Response Time out SS None 0 SS 200 mseconds 1 SS 500 mseconds 2 SS 800 mseconds 3 SS 1 second 4 SS 2 seconds 5 SS 3 seconds 6 SS 4 seconds 7 SS 5 seconds 8 SS 8 seconds 9 SS 10 seconds A SS 15 seconds B Baud Rate BPS SS 38 4K BPS 0 SS 19 2K BPS 1 SS 9600 BPS 2 SS 4800 BPS 3 SS 2400 BPS 4 SS 1200 BPS 5 SS 57 6K BPS 8 SS 115 2K BP...

Страница 43: ...served Subject to change without notice 43 3 5 5 Data Frame PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Data Frame SS 8 None 1 0 SS 8 Odd 1 1 SS 8 Even 1 2 SS 8 None 2 5 SS 7 Odd 1 6 SS 7 Even 1 7 SS 7 Space 1 8 SS 7 Mark 1 9 SS 7 None 2 A SS 7 Odd 2 B SS 7 Even 2 C SS 7 Space 2 D SS 7 Mark 2 E ...

Страница 44: ...level Margin Time SS 10 msec 0 SS 15 msec 1 SS 20 msec 2 SS 25 msec 3 SS 30 msec 4 Module Time SS Extremely short 0 SS Short 1 SS Medium 2 SS Long 3 Narrow Wide ratio SS 1 2 0 SS 1 2 5 1 SS 1 3 2 Code 39 Code 128 Emulation SS Disable standard Code 39 emulation 0 SS Enable standard Code 39 skip emulation 1 SS Enable standard Code 39 replace emulation 2 SS Enable Full ASCII Code 39 emulation 3 SS En...

Страница 45: ... character Standard Industrial 2 of 5 default I 07 1 character Interleaved 2 of 5 default J 08 1 character Matrix 2 of 5 default K 09 1 character China Postal Code default L 10 1 character German Postal Code default M 11 1 character IATA default O 12 1 character Code 11 default P 13 1 character MSI Plessey default R 14 1 character UK Plessey default S 15 1 character Telepen default T 16 1 characte...

Страница 46: ... default j 36 1 character Japan Post default k 37 1 character Netherlands KIX Post default l 38 1 character US Planet default m 39 1 character US Postnet default o 41 1 character 3 7 2 Symbology ID Transmission PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Symbology ID Transmission SS Disable symbology ID transmission 0 SS Enable prefix SICK symbology ID transmission ...

Страница 47: ...n P C Parameter Selection Option Code Readable Symbology SS Auto 00 CS Popular 1D CO CS Code 128 01 CS GS1 128 31 CS UPC A 02 CS UPC E 03 CS EAN 13 04 CS EAN 8 05 CS Codabar NW 7 06 CS Code 39 07 CS Trioptic Code 39 47 CS Standard Industrial 2 of 5 08 CS Matrix 2 of 5 38 CS Interleaved 2 of 5 48 CS China Postal Code 58 CS Germany Postal Code 68 CS Code 93 09 CS Code 11 10 CS MSI Plessey 11 CS UK P...

Страница 48: ... Han Xin code A4 CS Australian Post B0 CS British Post B1 CS Intelligent Mail barcode B3 CS Japanese Post B4 CS KIX Post B5 CS Planet Code B6 CS Postnet B8 Above symbologies marked with are enabled as default When you select Auto the scanner only reads those symbologies marked with Popular 1D includes Code 128 GSA 128 UPC A UPC E EAN 13 EAN 8 Codabar NW 7 Code 39 Interleaved 2 of 5 Code 93 GS1 Dat...

Страница 49: ... 32 leading A transmission 7 SS Enable Code 32 leading A transmission 8 SS Disable MOD 43 check digit verification 9 SS Enable MOD 43 check digit verification A SS Disable check digit transmission B SS Enable check digit transmission C SS Disable Code 39 buffering D SS Enable Code 39 buffering E Trioptic Code 39 Setting SS Disable Trioptic Code 39 0 SS Enable Trioptic Code 39 1 Code 39 Min Length ...

Страница 50: ...ode security for Code 39 bar codes Level 0 If you are experiencing misread of poorly printed or serious out of spec bar codes in level 1 please select level 0 Level 1 If you are experiencing misread of poorly printed or out of spec bar codes in level 2 please select level 1 Level 2 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decodi...

Страница 51: ...smission 8 SS Enable ABCD TN E start stop symbol transmission 9 SS Enable abcd tn e start stop symbol transmission A SS Disable check digit verification B SS Enable check digit verification C SS Disable check digit transmission D SS Enable check digit transmission E Codabar Check Digit Settings SS Modulus 16 0 SS Modulus 10 weight 3 1 SS Modulus 11 2 SS Modulus 10 weight 2 3 SS 7 check DR 4 SS Wei...

Страница 52: ...smission C SS Enable UPC E check digit transmission D SS Disable UPC leading 1 portion E SS Enable UPC leading 1 portion F When enable UPC E expansion the UPC E decoded data will be converted to UPC A format and affected by related settings such as UPC standardization UPC numeric system and UPC A check digit transmission UPC E EAN 8 Expansion Expand the 8 digit UPC E and 8 digit ENA 8 to 12 digit ...

Страница 53: ...r On 7 UPC EAN Security Level SS Level 0 0 SS Level 1 1 SS Level 2 2 Only available for UPC A EAN 13 Supplement Scan Vorting SS None 0 SS Level 1 1 SS Level 2 2 SS Level 3 3 SS Level 4 4 SS Level 5 5 SS Level 6 6 SS Level 7 7 SS Level 8 8 SS Level 9 9 SS Level 10 A SS Level 11 B SS Level 12 C SS Level 13 D UPC EAN Security Level The scanner offers three levels of decode security for UPC EAN bar co...

Страница 54: ... Supplement Scan Voting The Supplement Scan Voting is the number of times the same UPC EAN with 2 5 supplement digits has to be decoded before it is transmitted It is helpful when decoding a mix of UPC EAN symbols with and without supplement digits This function is effective when you select UPC EAN with only 2 supplement digits UPC EAN with only 5 supplement digits or UPC EAN with 2 5 supplement d...

Страница 55: ...ck digit transmission 8 SS Enable EAN 8 check digit transmission 9 SS Disable ISBN ISSN Conversion reading check A SS Enable ISBN ISSN Conversion reading check B EAN Supplement Settings SS Select EAN without supplement digits 0 SS Select EAN with only 2 supplement digits 1 SS Select EAN with only 5 supplement digits 2 SS Select EAN with 2 5 supplement digits 3 SS Disable force supplement digits ou...

Страница 56: ...able all specific prefix supplement digital output 0 SS Enable all specific prefix supplement digital output 1 SS Enable 491 Supplement Digit Output 2 SS Enable 978 979 Supplement Digit Output 3 SS Enable 977 Supplement Digit Output 4 SS Enable 378 379 Supplement Digit Output 5 SS Enable 414 419 Supplement Digit Output 6 SS Enable 434 439 Supplement Digit Output 7 UPC EAN Security Level SS Level 0...

Страница 57: ... scanner to operate fastest while providing sufficient security in decoding in spec UPC EAN bar codes Level 2 If you are experiencing misread of poorly printed soiled or damage bar codes in level 1 please select level 2 This is the most aggressive setting and may increase the misread 3 7 9 UCC Coupon Extended Code PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code UCC Coup...

Страница 58: ...erification 5 SS Enable S N checking digit verification only 6 SS Enable CPN checking digit verification only 7 SS Enable CPN Airline and S N check digit verification 8 SS Disable check digit transmission 9 SS Enable check digit transmission A SS Disable start stop symbol transmission B SS Enable start stop symbol transmission C Interleaved 2 of 5 Settings SS Disable Interleaved 2 of 5 0 SS Enable...

Страница 59: ...fication 6 SS Enable check digit verification 7 SS Disable check digit transmission 8 SS Enable check digit transmission 9 Code 25 Family Min Length SS Default 04 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Code 25 Family Max Length SS Default 98 FIN MS 01 98 2 digits Scan 2 digits from the option code ...

Страница 60: ...ts Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Code 11 Max Length SS Default 98 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Code 39 Settings SS Disable Code 93 0 SS Enable Code 93 1 SS Disable check digit transmission 2 SS Enable ...

Страница 61: ...ey 1 SS Select MOD 10 check digit 2 SS Select MOD 10 10 check digit 3 SS Select MOD 11 10 check digit 4 SS Disable check digit transmission 5 SS Enable check digit transmission 6 MSI Plessey Min Length SS Default 04 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically MSI Plessey Max Length SS Default 98 FIN MS ...

Страница 62: ...ode 128 Max Length SS Default 98 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Code 128 Security Level SS Level 0 0 SS Level 1 1 Code 128 Setting ISBT Concatenation Off The scanner will not output ISBT concatenated barcodes ISBT Concatenation On The scanner will only decode and output ISBT concatenated ba...

Страница 63: ... 63 Code 128 Security Level The scanner offers two levels of decode security for Code128 bar codes Level 0 If you are experiencing misread of poor printed or out of spec bar codes in level 1 please select level 0 Level 1 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decoding in spec Code 128 bar codes ...

Страница 64: ...in the Appendix then the scanner will terminate this selection automatically GS1 128 Max Length SS Default 98 FIN MS 98 Minimum 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically GS1 128 Edition Mode SS None FIN MS 1 10 Application Identifier AIs and Prefix Suffix input AI table 2 GS1 128 ASCII table 3 FIN Please scan the ...

Страница 65: ...128 ASCII Table 1 FIN GS1 128 Error Output Setting SS When Code 128 is converted into GS1 128 no data output when Code 128 is read 0 SS Read and data output of Code 128 even when Code 128 is converted to GS1 128 1 When the decode is not done as GS1 128 GS1 DataBar Output Control SS Disable GS1 DataBar RSS 14 output application identifier with additional 0 SS Enable GS1 DataBar RSS 14 output applic...

Страница 66: ...Plessey Standard Format 2 SS Select UK Plessey CLSI Format 3 SS Disable Convert X to A F 4 SS Enable Convert X to A F 5 SS Disable check digit transmission 6 SS Enable check digit transmission 7 UK Plessey Min Length SS Default 04 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically UK Plessey Max Length SS Defa...

Страница 67: ...nable Telepen 1 SS Select Telepen Numeric mode 2 SS Select Telepen Full ASCII mode 3 SS Disable check digit transmission 4 SS Enable check digit transmission 5 Telepen Min Length SS Default 04 FIN MS 01 98 2 digits Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Telepen Max Length SS Default 98 FIN MS 01 98 2 digits Scan 2 digit...

Страница 68: ...1 DataBar Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically GS1 DataBar Max Length SS Default 74 FIN MS 01 74 2 digits Only available for Expanded GS1 DataBar Scan 2 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically GS1 128 Limited Security Level The scanner IDM120 serie...

Страница 69: ...composite codes 0 SS Enable composite codes 1 SS UPC Composite Mode UPC never linked 2 SS UPC Composite Mode UPC always linked 3 If UPC Composite Mode UPC never linked is selected UPC barcodes are transmitted whether Micro PDF417 symbol is detected or not If UPC Composite Mode UPC always linked is selected UPC barcodes are only transmitted when the Micro PDF417 is detected Codablock F Settings SS ...

Страница 70: ...ix then the scanner will terminate this selection automatically Code 16K Max Length SS Default 160 FIN MS 001 160 3 digits Scan 3 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Code 49 Settings SS Disable Code 49 0 SS Enable Code 49 1 Code 49 Min Length SS Default 01 FIN MS 01 81 2 digits Scan 2 digits from the option code chart in th...

Страница 71: ... Enable MicroQR Code 3 SS Disable QR Code Append 4 SS Enable QR Code Append 5 SS Disable QR Code Inverse Reading 6 SS Enable QR Code Inverse Reading 7 SS Auto detect QR Code Inverse Reading 8 QR Code Min Length SS Default 0001 FIN MS 0001 7089 4 digits Scan 4 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically QR Code Max Length SS Default...

Страница 72: ...h SS Default 0001 FIN MS 0001 3116 4 digits Scan 4 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Data Matrix Max Length SS Default 3116 FIN MS 0001 3116 4 digits Scan 4 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Small DM Code Reading SS Standard 0 SS Level 1 1 SS Lev...

Страница 73: ...ction Option Code Aztec Code Settings SS Disable Aztec Code 0 SS Enable Aztec Code 1 Aztec Code Min Length SS Default 0001 FIN MS 0001 3832 4 digits Scan 4 digits from the option code chart in the Appendix then the scanner will terminate this selection automatically Aztec Code Max Length SS Default 3832 FIN MS 0001 3832 4 digits Scan 4 digits from the option code chart in the Appendix then the sca...

Страница 74: ... Table 5 US Planet Settings SS Disable US Planet 0 SS Enable US Planet 1 SS Disable Check Digit Transmission 2 SS Enable Check Digit Transmission 3 US Postnet Settings SS Disable US Postnet 0 SS Enable US Postnet 1 SS Disable Check Digit Transmission 2 SS Enable Check Digit Transmission 3 British Post Settings SS Disable British Post 0 SS Enable British Post 1 SS Disable Check Digit Transmission 2...

Страница 75: ...t Mail Korea Post Code PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Netherlands KIX Code Settings SS Disable Netherlands KIX Code 0 SS Enable Netherlands KIX Code 1 Intelligent Mail Settings USPS 4CB One Code SS Disable Intelligent Mail 0 SS Enable Intelligent Mail 1 Korea Post Code Settings SS Disable Korea Post Code 0 SS Enable Korea Post Code 1 Length fixed in 6 c...

Страница 76: ...n P C Parameter Selection Option Code MaxiCode Setting SS Disable MaxiCode 0 SS Enable MaxiCode 1 MaxiCode Min Length SS Default 01 FIN MS 01 Maximum 3 digits Scan 3 digits from the option code chart in Appendix then IDM will terminate this selection automatically MaxiCode Max Length SS Default 150 FIN MS 150 Minimum 3 digits Scan 3 digits from the option code chart in Appendix then IDM will termi...

Страница 77: ...ty Disable DPM functionality In order to verify if the DPM functionality is enabled please scan the following barcode If you can read this barcode the DPM functionality is enabled Test1 IDM Corded scanners if you scan factory default and afterwards disconnect the scanner from your host device the DPM functionality will be disabled automatically IDM Bluetooth scanners if you take out the battery th...

Страница 78: ...ith power saving Trigger Mode External Triggering The scanner goes into standby state after scanning the barcode You must press the trigger to turn on the light source of the scanner before scanning the bar code Presentation Mode Auto Detection Presentation mode uses ambient light to detect the barcodes The light source is off until the scanner detects an image which is similar to a barcode Then t...

Страница 79: ...to scan The scanner keeps the light source turned on until you press the trigger again Diagnostic Mode Test Reading This operation mode is specifically designed for diagnostic purposes When this operation mode is selected the light source of the scanner is force on without regard for other programmable parameters such as reread delay redundancy and so forth Level Mode Auto Power Off When this oper...

Страница 80: ...SS Buzzer tone mute 0 SS Buzzer tone low Frequency 1 20 kHz 1 SS Buzzer tone medium Frequency 2 70 kHz 2 SS Buzzer tone high Frequency 2 81 kHz 3 SS Buzzer tone extremely high Frequency 2 93 kHz 4 SS Power on power off beep 5 SS No power on power off beep 6 Power On Indicator SS Disable LED off 0 SS LED steady on 1 SS LED flash 2 IDM120 series doesn t support this function Good Read Indicator SS D...

Страница 81: ...7159 142O 2019 05 23 SICK AG Germany All rights reserved Subject to change without notice 81 3 9 2 Buzzer Volume PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Buzzer Volume SS Low 0 SS Medium 1 SS High 2 Buzzer Volume Available for IDM 2xx 3 ...

Страница 82: ...ndancy 1D Code Inverse Reading PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Redundancy SS None 0 SS Level 1 1 SS Level 2 2 SS Level 3 3 SS Level 4 4 SS Level 5 5 The Redundancy is the number of times the same barcode has to be decoded before it is transmitted To prevent potential misreading 1D Barcode Inverse Reading SS Disable 0 SS Enable 1 ...

Страница 83: ...digits from the option code chart in Appendix then IDM will terminate this selection automatically The Reread Delay Double Scan Verification This function is designed to inhibit the Hand held scanner from reading the same bar code label twice in pre defined short duration Force Verification will not allow the reading of the same bar code twice IDM1x0 The Reread Delay function is only available whe...

Страница 84: ... Out SS Short 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Disable 4 Good Read Duration SS Short 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Extremely short 4 Time Delay to Low Power Standby Mode SS 1 sec 0 SS 3 sec 1 SS 5 sec 2 SS 7 sec 3 SS 9 sec 4 SS Immediate 5 Low Power Standby mode Link Indication SS Turn off immediately 0 SS Last for 1 minute 1 SS Keep on till power off 2 Light Source ...

Страница 85: ...n the scanner in manual trigger mode by setting the Hands Free Time Out Once the time out duration is up if there isn t any trigger operation the imager will revert to the original hands free mode Good Read Duration Use Good Read Duration Good Read Beep and Vibration Duration to define beeps and vibration according to operator preference and work environment Time Delay to Low Power Standby Mode Th...

Страница 86: ...nable 1 Presentation Sensitivity SS Level 1 0 SS Level 2 1 SS Level 3 2 SS Level 4 3 SS Level 5 4 SS Level 6 5 SS Level 7 6 Presentation Auto sense When enabling the Presentation Auto sense the scanner can switch automatically from hand held to hands free scanning when working with the Hands free stand or cradle Presentation Sensitivity The presentation sensitivity is used to configure the sensiti...

Страница 87: ...2 duty cycle 0 SS 2 3 duty cycle 1 SS 3 4 duty cycle 2 SS 4 5 duty cycle 3 Presentation Control When the scanner is placed on the Hands free stand the scanner will be switched from hand held scanning to hands free scanning automatically Three hands free scanning modes are available You are recommended to use flash mode or force mode while under insufficient ambient light Scan Rate Control The scan...

Страница 88: ...0 2D Corded IDM2x0 1D BT IDM1x1 2D BT IDM2x1 Illumnation Control SS Disable 0 0 SS Enable 1 1 Not available for presentation force and diagnostic mode Presentation Background Lighting SS LEDs Off 0 0 SS LEDs On 1 1 Presentation Background Lighting Control You can enable or disable presentation background lighting of the scanner according to the ambient light condition in presentation mode When the...

Страница 89: ...nds Free mode 2 2 SS Enable in Hands Free mode 3 3 Aiming Control The Aiming Control is only available for trigger mode In Intelligent Aiming the aiming light is turned on when the scanner is lifted A trigger pull activates decoding process After 2 seconds of inactivity the aiming light will be shut off Delay Aiming Control allows a delay time for the operator to aim the scanner before the image i...

Страница 90: ... Hands Free mode 3 3 Unique Barcode Reporting SS Disable 0 0 SS Enable 1 1 Center Alignment When this function is enabled the scanner only decodes barcode s around the aiming line Unique Bar Code Reporting When this function is enabled the scanner will only output data from each barcode once during a scanning cycle trigger key pressed and held without release This prevents the output of repeat dat...

Страница 91: ...D Corded IDM1x0 2D Corded IDM2x0 1D BT IDM1x1 2D BT IDM2x1 1D Barcode Forward reading Indication SS None 0 SS S 1 MS User defined character 1 character 2 00 7F 1D Barcode Backward reading Indication SS None 0 SS X 1 MS User defined character 1 character 2 00 7F 1D Barcode Direction Indication Transmission SS Disable 0 SS Enable prefix direction mark transmission 1 SS Enable suffix direction mark t...

Страница 92: ...tion Option Code Motion Control SS Level 1 0 SS Level 2 1 SS Level 3 2 SS Level 4 3 The scanner will have better motion tolerance when you select higher level The higher lever means higher motion tolerance It s suitable for application which needs higher motion tolerance on the move But this may impact to the reading distance and the readability of high dense barcodes If the ambient light is dim o...

Страница 93: ...clock Time Conversion 14 56 set 1456 Timestamp Format Setting SS HH MM DD MM YYYY 0 SS HH MM MM DD YYYY 1 SS HH MM YYYY MM DD 2 SS HH MM SS DD MM YYYY 3 SS HH MM SS MM DD YYYY 4 SS HH MM SS YYYY MM DD 5 SS DD MM YYYY HH MM 6 SS MM DD YYYY HH MM 7 SS YYYY MM DD HH MM 8 SS DD MM YYYY HH MM SS 9 SS MM DD YYYY HH MM SS 10 SS YYYY MM DD HH MM SS 11 SS DD MM YYYY 12 SS MM DD YYYY 13 SS YYYY MM DD 14 SS ...

Страница 94: ...Option Code Stored Data Output Format SS Data Record 0 SS Quantity Data Record 1 SS Data Record Quantity 2 SS Timestamp Data Record 3 SS Data Record Timestamp 4 SS Timestamp Quantity Data Record 5 SS Timestamp Data Record Quantity 6 SS Quantity Timestamp Data Record 7 SS Quantity Data Record Timestamp 8 SS Data Record Timestamp Quantity 9 SS Data Record Quantity Timestamp 10 Online Mode Output For...

Страница 95: ...tions When scanning common retail barcodes you can set the scanner to Scene 3 to optimize scanner s motion tolerance scanning speed and scanning sensitivity Scene 4 Scene 4 is also for general retail applications lt optimizes the scanner s sensitivity and speed when scanning common retail barcodes Moreover it provides superior reading performance when scanning barcodes from the screens of mobile d...

Страница 96: ...ected disconnected Beep On 0 SS Radio connected disconnected Beep Off 1 SS Battery Power Low Beep On 2 SS Battery Power Low Beep Off 3 Radio Connection Beeps SS Four ascending tone Four descending tone 0 SS Low high two beeps High low two beeps 1 Out of range Scanning When radio link is built between the scanner and remote host device the scanner will transmit each scanned data right after scannin...

Страница 97: ...er to enter sleep mode please set time out to 0 Power Off Time Out SS 6 x5 minutes FIN MS 0 12 minutes 2 digits If you don t want the scanner to enter power off mode please set time out to 0 Radio off Time out control The Radio off Time out control can be set under radio connection or disconnection state If the scanner is not used within the preset time out duration it will automatically enter Sle...

Страница 98: ...ACE 2 SS 3 SS 4 SS User define 5 00 7F Batch Data Quantity Output Format SS As many times as the quantity indicates 0 SS Quantity Field Delimiter Scanned Data 1 SS Scanned Data Field Delimiter Quantity 2 Data Transmission Format SS Disable scanned data only 0 SS Leading with MAC address MAC address scanned data 1 SS Leading with ID No Scanner ID scanned data 2 Only available for RS 232 USB HID and...

Страница 99: ... you enable this function all stored data will automatically be deleted after transmission Field Delimiter This function is used to separate the specific information and the scanned data into two fields You can choose the delimiter format Batch Data Quantity Output Format If you want to input the quantity information of the scanned barcode data you can enter the quantity from 1 to 9999 by scanning...

Страница 100: ... IDM1xx 1 16 characters IDM2xx 1 32 characters 00 7F FIN The default device name is IDMxxx Bluetooth PIN Code SS Default Bluetooth PIN Code FIN MS User defined 1 8 numbers 30 39 FIN The default PIN code is 00000000 Bluetooth Authentication SS Disable 0 SS Enable 1 Bluetooth Authentication You can enable or disable the Bluetooth Authentication between the scanner and remote host device If this func...

Страница 101: ... SS Level 1 1 SS Level 2 2 SS Level 3 3 SS Level 4 4 Bluetooth Power Saving Mode SS Disable 0 SS Enable 1 Link Quality Setting This function is only available for SPP and HID mode When you use the scanner in the boundary of radio signal you can enable this function to increase the reliability of data transmission But this function will affect the communication distance The level is higher the comm...

Страница 102: ...unction is only available for 2D Hand held scanners IDM2xx series Batch Reading function is only available in Trigger Mode Batch Reading is not available when Multiple Read Mode or Center Alignment is turned on Batch Reading Rule To set the Batch Reading rule 1 Scan the PROGRAM code 2 Scan the Batch Reading Family Code 3 Use the Option Codes to define the preset Batch Reading rule 4 Scan the FIN s...

Страница 103: ... which are counted from the start character of the whole Data String Note When setting the matched character s you must match the content of the whole Data String including the programmed Preamble Postamble Scanned Data Length Prefix Suffix Symbol ID or AIM ID FF is the universal character indicating all characters Batch Reading Rule Example In this example you are scanning Code 39 Code 128 and Co...

Страница 104: ...ode length that must match for Code 128 A Code 128 sample length 10 plus Suffix Symbol ID 1 11 41 Start character match for Code 128 41h A FF End of first code 07 Code identifier of Code 39 0011 Code length that must match for Code 39 BC CODE 39 sample length 10 plus Suffix Symbol ID 1 11 FF Universal matched character indicating all characters Also indicates end of second code 09 Code identifier ...

Страница 105: ...via bar code menu readings with ease All Character input should be referred to the ASCII HEX Table listed in the Appendix page 119 to find the matched HEX value 3 12 1 Preamble Postamble Data Length Symbol ID Transmission PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Preamble SS None FIN MS 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate thi...

Страница 106: ...aracters FIN Define position refer to chapter 3 12 7 max 3 characters can be inserted 2nd insertion SS Disable FIN DS Enable Position 2 digits 1 3 characters FIN Define position refer to chapter 3 12 7 max 3 characters can be inserted 3rd insertion SS Disable FIN DS Enable Position 2 digits 1 3 characters FIN Define position refer to chapter 3 12 7 max 3 characters can be inserted 4th insertion SS...

Страница 107: ...ix Regarding the Bar Code Selection and Position Calculation of Data Verifier please refer to page 110 and 111 for details All Character input should be referred to the ASCII HEX Table listed in the Appendix page 119 to find matched HEX value PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection 1st Option Code 2nd Option Code Verifier Control SS Disable FIN MS Select one barcode symbolo...

Страница 108: ...gth Prefix Suffix Symbology ID or Record Suffix Regarding the Bar Code Selection and Position Calculation of Data Replacer please refer to page 110 and 111 for details All Character input should be referred to the ASCII HEX Table listed in the Appendix page 119 to find matched HEX value PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection 1st Option Code 2nd Option Code Replacer Control...

Страница 109: ... Prefix Suffix Symbology ID or Record Suffix Regarding the Bar Code Selection and Position Calculation of Data Organizer please refer to page 110 and 111 for details All Character input should be referred to the ASCII HEX Table listed in the Appendix page 119 to find matched HEX value PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection 1st Option Code 2nd Option Code Organizer Control ...

Страница 110: ... 07 GS1 DataBar 14 UPC A with 2 supplement 32 Code 32 37 IATA 15 UPC A with 5 supplement 42 Trioptic Code 39 47 Coupon Code 16 UPC E 03 Matrix 2 of 5 38 PDF417 Micro PDF417 17 UPC E with 2 supplement 33 Interleaved 2 of 5 48 Codablock F 18 UPC E with 5 supplement 43 China Postal Code 58 Code 16K 19 EAN 13 04 German Postal Code 68 Code 49 20 EAN 13 with 2 supplement 34 Standard Industrial 2 of 5 08...

Страница 111: ... code 6 digit serial number and 4 digit unit price you want the Hand held scanner to do the following for you without software modification Apply only Interleaved 2 of 5 to the condensed DataWizard Check bar code is actually with 16 digit length Allow bar code output whose date code is leading with 9 Three outputs with TAB suffix The date code output should skip 9 and replaced it by A The serial n...

Страница 112: ...nd you must scan FIN Finish code to terminate this selection Data Replacer Scan Replacer Control and set the barcode symbology to 48 Scan 1st Replacement and set the identified position to 00 then replaced character to 41 Hex Code of A Data Organizer Scan Organizer Control and set the barcode symbology to 48 Scan 1st Organization and set the identified position to 16 then set the data transmission...

Страница 113: ...s will be downloaded to the scanner After a successful download you can close the IDM Set Up Tool 4 1 2 IDM Bluetooth Scanners 1 Make sure that the Scanner is paired with the base station pair mode 2 The interface has to be set to RS232 or USB COM You can test the communication with any terminal program After testing close the terminal program so that the com port is free again 3 Scan the Uninstal...

Страница 114: ...p Host Link codes IDM Set Up Tool Host Link 7 Choose the right Com Port 8 Press Upgrade 9 The screen will dim and the firmware will begin uploading to the scanner You will hear some beeps while the process takes place Do not interrupt the upgrading process 10 After a successful firmware upgrade click on Abort 4 2 2 IDM Bluetooth Scanner 1 Connect the smart cradle with your PC 2 Scan the Uninstall ...

Страница 115: ...linking green before you release the Paging Reset Button This step in the process automatically places the cradle in USB COM Emulation mode 7 Do not place the scanner back into the cradle 8 Open the IDM Set Up Tool 9 Click on Upgrade The open file box will open 10 In the tree menu find the location of the cradle firmware 11 Choose the Smart Cradle firmware and click OK 12 Choose the correct Com Po...

Страница 116: ...ent regulations and directives for the disposal of industrial and electronic waste According to international directives batteries accumulators and electrical or electronic devices must not be disposed of in general waste The owner is obliged by law to return products at the end of their life to the respective public collection points This symbol on the product its package or in this document indi...

Страница 117: ... Postal Code 68 M I M IATA IATA 15 O R M UCC Coupon UCC Coupon Code Z Example An UPC A 512345678900 GS1 128 81010123451297 barcode is transmitted as E0512345678900 C181010123451297 Example An EAN 13 9923456789019 GS1 128 81010123451297 barcode is transmitted as E09923456789019 C181010123451297 EAN JAN EAN JAN 8 05 N E 4 EAN JAN 8 with 2 supple 35 1 EAN JAN 8 with 5 supple 45 2 EAN JAN 13 04 F E 0 ...

Страница 118: ...l R 03 ETX 03H SHIFT Ctrl C 19 DC3 13H F10 Ctrl S 04 EOT 04H CAPS LOCK Ctrl D 20 DC4 14H F11 Ctrl T 05 ENQ 05H NUM LOCK Ctrl E 21 NAK 15H F12 Ctrl U 06 ACK 06H ESC Ctrl F 22 SYN 16H INS Insert Edit Ctrl V 07 BEL 07H F1 Ctrl G 23 ETB 17H DEL Delete Edit Ctrl W 08 BS 08H BACK SPACE Ctrl H 24 CAN 18H HOME Edit Ctrl X 09 HT 09H TAB Ctrl I 25 EM 19H END Edit Ctrl Y 10 LF 0AH F2 Ctrl J 26 SUB 1AH PAGE U...

Страница 119: ...s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o DEL Example ASCII A HEX 41 ASCII a HEX 61 High Byte of HEX Value Low Byte of HEX Value Example If you want the scanned data output leading with a Dollar Sign you have to set the Preamble to The configu...

Страница 120: ...0 None for AI prefix suffix NUL for others N A 14 DC4 Ctrl T 01 SOH Ctrl A 15 NAK Ctrl U 02 STX Ctrl B 16 SYN Ctrl V 03 ETX Ctrl C 17 ETB Ctrl W 04 EOT Ctrl D 18 CAN Ctrl X 05 ENQ Ctrl E 19 EM Ctrl Y 06 ACK Ctrl F 1A SUB Ctrl Z 07 BEL Ctrl G 1B ESC N A 08 BS Ctrl H 1C FS N A 09 HT Ctrl I 1D GS N A 0A LF Ctrl J 1E RS N A 0B VT Ctrl K 1F US N A 0C FF Ctrl L 20 SP SP 0D CR Ctrl M 21 0E SO Ctrl N 22 0...

Страница 121: ... 121 2E 45 E E 2F 46 F F 30 0 0 47 G G 31 1 1 48 H H 32 2 2 49 I I 33 3 3 4A J J 34 4 4 4B K K 35 5 5 4C L L 36 6 6 4D M M 37 7 7 4E N N 38 8 8 4F O O 39 9 9 50 P P 3A 51 Q Q 3B 52 R R 3C 53 S S 3D 54 T T 3E 55 U U 56 V V 6D m m 57 W W 6E n n 58 X X 6F o o 59 Y Y 70 p p 5A Z Z 71 q q 5B 72 r r 5C 73 s s 5D 74 t t 5E 75 u u 5F _ _ 76 v v 60 77 w w 61 a a 78 x x ...

Страница 122: ... F1 6A j j 81 N A F2 6B k k 82 N A F3 6C l l 83 N A F4 84 N A F5 91 N A Left Arrow 85 N A F6 92 N A PageUp 86 N A F7 93 N A PageDown 87 N A F8 94 N A Enter 88 N A F9 95 N A Delete 89 N A F10 96 N A Insert 8A N A F11 97 N A Home 8B N A F12 98 N A End 8C N A Tab 99 N A BackSpace 8D N A Esc 9A N A Shift 8E N A Down Arrow 9B N A Ctrl 8F N A Up Arrow 9C N A Alt 90 N A Right Arrow Shift Ctrl and Alt Rea...

Страница 123: ... 13 Unnecessary 313D Unnecessary 15 Unnecessary 314D Unnecessary 17 Unnecessary 315D Unnecessary 20 Unnecessary 316D Unnecessary 21 Indispensability FNC1 320D Unnecessary 22 Indispensability FNC1 321D Unnecessary 23L Indispensability 322D Unnecessary Data field length 2L 1 Example 231 it is 2 1 1 3 240 Indispensability FNC1 323D Unnecessary 241 Indispensability FNC1 324D Unnecessary 250 Indispensa...

Страница 124: ...ability FNC1 390D Indispensability FNC1 7030 Indispensability 391D Indispensability FNC1 7031 Indispensability 392D Indispensability FNC1 7032 Indispensability 393D Indispensability FNC1 7033 Indispensability 400 Indispensability FNC1 7034 Indispensability 401 Indispensability FNC1 7035 Indispensability 402 Indispensability FNC1 7036 Indispensability 403 Indispensability FNC1 7037 Indispensability...

Страница 125: ...Indispensability FNC1 93 Indispensability FNC1 8018 Indispensability FNC1 94 Indispensability FNC1 8020 Indispensability FNC1 95 Indispensability FNC1 8100 Indispensability FNC1 96 Indispensability FNC1 8101 Indispensability FNC1 97 Indispensability FNC1 8102 Indispensability FNC1 98 Indispensability FNC1 90 Indispensability FNC1 99 Indispensability FNC1 91 Indispensability FNC1 ...

Страница 126: ...st Interface Quick Set USB HID Standard Mode PS 2 DOS V KBW Standard Mode RS 232 Serial USB Com Port Emulation PS 2 DOS V KBW Turbo Mode additional driver needed available on www sick com USB HID Turbo Mode PS 2 DOS V Keyboard Replacement USB HID Legacy Mode For IDM Bluetooth scanners the above host interface quick commands are only available when working with a smart cradle ...

Страница 127: ...ubject to change without notice 127 6 8 Operation Mode Quick Set 6 8 1 1D Corded Scanners IDM1x0 series Low Power Low Power Trigger Force Continued power on Alternative Periodic Power off Trigger External Triggering Toggle Repeat reading Flash Pulse driven reading Presentation Auto Sensing Diagnostic Test reading Level Auto power off ...

Страница 128: ...tice 8017159 142O 2019 05 23 6 8 2 2D Corded Scanners IDM2x0 series Low Power Low Power Trigger Force Continued power on Alternative Periodic Power off Trigger External Triggering Toggle Repeat reading Level Auto power off Presentation Auto Sensing Diagnostic Test reading Multiple Read 6 8 3 Bluetooth Scanners Trigger Mode Presentation Mode ...

Страница 129: ...142O 2019 05 23 SICK AG Germany All rights reserved Subject to change without notice 129 6 9 Link Mode Quick Set The Link Mode commands are only relevant for IDM Bluetooth scanners PAIR Mode PICO Mode Uninstall SSP Master SSP Slave HID Mode HID Legacy Mode HID Mode with Passkey ...

Страница 130: ...scanner will revert to uninstall state Master Default After scanning Master Default command the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Interface Control except Record Suffix Preamble Postamble and Wand Laser Emulation Control The rest of the parameters will be returned to default value For IDM...

Страница 131: ...Commands IDM corded IDM Bluetooth 8017159 142O 2019 05 23 SICK AG Germany All rights reserved Subject to change without notice 131 Additional System Commands for IDM Bluetooth Scanners Sleep Save Configuration Power Off Paging Clone ...

Страница 132: ...rating Instructions IDM corded IDM Bluetooth 132 SICK AG Germany All rights reserved Subject to change without notice 8017159 142O 2019 05 23 6 11 Option Codes 0 A 5 1 B 6 2 C 7 3 D 8 4 E 9 F Abort FIN Finish END Exit ...

Страница 133: ...Operating Instructions Option Codes IDM corded IDM Bluetooth 8017159 142O 2019 05 23 SICK AG Germany All rights reserved Subject to change without notice 133 ...

Страница 134: ... Japan Phone 81 3 5309 2112 E Mail support sick jp Malaysia Phone 603 8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E Mail sales sick co nz Norway Phone 47 67 81 50 00 E Mail sick sick no Poland Phone 48 22 539 41 00 E Mail info sick pl Romania Ph...

Отзывы: