Installation
FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V2-1/2021-05 · © SICK Engineering GmbH
71
Su
bje
ct to
ch
an
ge
w
ith
ou
t n
otic
e
3.4.8.2
Connection parameters Ex-d and Ex-e
Table 6
Connection parameters Ex-d and Ex-e
NOTICE:
Safety-relevant parameters Ex-i
The connection parameters in
do not apply for the Ex- i installation.
Safety-relevant parameters for Ex-i installation, see
installation according to ATEX/IECEx and
for installation
according to CSA.
Ex-d
Ex-e
Connection parameters
Power supply
Power
1 + 2
10.8 ...26.4 VDC, max. 400 mA
Switching outputs
DO.0/FO.0
13+14
Open Collector, max. 30 VDC,
max. 50 mA,
switching frequency DC ...10 kHz,
recommended switching current
2 mA < Ic < 20 mA,
load resistance R
load
= U / Ic,
alternative NAMUR characteristic
DO.1/FO.1
15+16
DO.2
17+18
DO.3
19+20
Encoder
Encoder
9+10
NAMUR, 1.2 kbit/s, UART protocol 7E1
Active current output AO
5-8
24 VDC, 3.6 ...24 mA,
alternative external auxiliary voltage
max. 30 V,
Pressure and tem
-
perature sensor sys
-
tem
pT
(HART Master)
3+4
[1]
[1] If configured
Configuration options and power input of possible configurations, see → p. 158, §9.4.
24 VDC, max. 24 mA,
RS485
RS485.1
21+22
[1]
EIA-485, max. 57.6 kbit/s,
termination 150 Ohm switchable
Configuration of the RS485.1 interface at
the factory:
– Protocol type: MODBUS-RTU
– Modbus configuration: FL600XT
(standard)
– Baud rate: 38,400 baud
– Bit protocol: 8N1
RS485.2
3+4
[1]
RS485.3
9+10
[1]
Ethernet
Ethernet
9-12
[1]
10/100 Mbit/s, protocol Modbus TCP