142
FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V2-1/2021-05 · © SICK Engineering GmbH
Annex
Su
bje
ct to
ch
an
ge
w
ith
ou
t n
otic
e
Fig. 73
Connection diagram 9236581 (page 5)
V
er
vielfaeltigung
dieser
Unterlage
sowie
V
er
wertung
und
Mitteilung
ihres
Inhaltes
unzulaessig
,
soweit
nicht
ausdruecklich
zugestanden
.
Zuwiderhand-
lungen
sind
strafbar
und
verpflichten
zu
Schadenersatz
(LitUrhG
,
UWG
,
BGB).
Alle
R
echte
fuer
den
F
all
der
Patenterteilung
oder
GM-Eintragung
vorbehalten
.
A4_F
ormblatt_ME10.CDR
SICK
Engineering
GmbH
Bergener
Ring
27
01458
Ottendorf-Okrilla
V
erteildatum:
Page
Norm-
Typ/DIN
Ersatz
für:
Änderung
gepr
.
gez.
Ta
g
Name
T
ag
Name
Maßst
ab:
W
erkstof
f
Ersetzt
durch:
Gepr
.
Ursprung:
5o
f1
5
Safety
p
arameters
of
interconnected
equipment
s
must
be
complied
as
follows:
Uo
<
Ui,
Io
<
Ii,
Po<
Pi,
Co
>
Ci
+
Ccable,
Lo
>
Li
+
Lcable
Hazardous
(classified)
location
Safe
Area
9236581
Associated
Equipment
Uo
<=
20
V
,
Po
<=
717
mW
Uo
<=
20
V
,
Po
<=
717
mW
Uo
<=
20
V
,
Po
<=
717
mW
Uo
<=
20
V
,
Po
<=
717
mW
Uo
<=
10.5
V
Po
<=
717
mW
Co
>=
1.21
μF
+
C
Lo
>=
0.02
mH
+
L
cable
cable
Uo
<=
18.2
V
Po
<=
1
W
Uo
<=
10.5
V
Po
<=
717
mW
Co
>=
1.21
μF
+
C
Lo
>=
0.02
mH
+
L
cable
cable
+ -
+
-
+
-
+
-
+
-
SPU
I/Oconfiguration
withmodules
“DO-LF”
+2
x“RS485”
+“ENCODER”
A
B
+
-
+
-
A
B
+
-
Ui
=
10.5
V
Pi
=
717
mW
Ci
=
1.21
μF
Li
=
0.02
mH
RS485
optical
isolated
needs
ext.
power
A
B
+
-
Ui
=
18.2
V
P
i=1W
ENCODER
optical
isolated
+
-
Ui
=
10.5
V
Pi
=
717
mW
Ci
=
1.21
μF
Li
=
0.02
mH
RS485
optical
isolated
needs
ext.
power
A
B
+
-
U
i=2
0V
Pi
=
717
mW
U
i=2
0V
Pi
=
717
mW
U
i=2
0V
Pi
=
717
mW
U
i=2
0V
Pi
=
717
mW
+
-
+
-
+
-
+
-
DO.3
optical
isolated
DO.2
optical
isolated
FO.1
optical
isolated
FO.0
optical
isolated
DO-LF
Moduleslot
UART3
Moduleslot
UART2
Moduleslot
UART0
Moduleslot
Digital
outputs
withPower
input
T
emperature
range
and
pressure
range
see
Marking
plate
internalSPI
pressuresensor
notavailable
for
Tgas>105°C
Up
to
16
ultrasonic
transducers,
only
manufactured
by
SICK
ext.
Power
6...16
Vdc
-+-+
kochami
kochami
2015-10-30
Control
Drawing
FLOWSIC600-XT
CSA
Ind.
2016-01-27
W
ARNING:
A
VERTISSEMENT
:
EXPLOSION
HAZARD
Substitution
of
component
s
may
imp
air
Intrinsic
safety
RISQUE
D`
EXPLOSION
-
La
substitution
de
composant
s
peut
compromettre
la
securite
intrinseque.
Class
I
Division
1,
Group
s
A,
B,
C,
D,
T4
Ex
ia
Intrinsically
Safe;
Securite
Intrinseque
Ex
ia
IIC
T4
Ga
Class
I
Zone
1
AEx
ia
op
is
IIC
T4
Ga
-40°C
<
T
amb
<
70°C
In
the
US
inst
all
in
accordance
with
the
NEC
(NFP
A70,
Article
504)
and
ANSI/ISA-RP12.06.01
In
Canada
inst
all
in
accordance
with
CEC
p
art
1.
Read
operation
instructions
before
inst
allation.
FLOWSIC600-XT
(F6*-******-*I1J-****)
U
i=2
0V
Ii
=
667
mA
Pi
=
1.65
W
Li
=
0.005
mH
Uo
<=
20
V
Io
<=
667
mA
Po
<=
1.65
W
Lo
>=
0.005
+
Lcable
01
ZAK3
kochami
kochami
2017-03-29
2017-03-29