Operation
2.3
Control Panel
The following display of the DME4000 appears after you connect operating voltage (or after a reset):
Illustration 2.2 – Display after Connection of Operating Voltage
The DME4000 is ready to operate after approx. 1 s and displays the current measurement value:
2.3.1
Status indicators
Display
Significance
Is Displayed
Is not Displayed
MF1
Multifunctional
input/output
Input/output level active
Input/output level not active
MF2
Multifunctional output
Output level active
Output level not active
TMP
Internal sensor temperature
Pre-failure message:
Internal sensor temperature at
fringe range
Internal sensor temperature OK
ATT
Attenuation
Pre-failure message:
Reception signal level at fringe
range
Reception level OK
LSR
Laser
Pre-failure message for
measurement laser
Laser OK
PLB
Plausibility
Measurement error
cause: Light beam interruption,
speed
>
10 m/s
Measurement value OK
RDY
Ready
At ready-to-operate state
Initialization, hardware defect
BUS
SSI/PROFIBUS/RS 422/
DeviceNet/CANopen interface
SSI: clock signal received
PB/DN: telegram traffic
RS 422: continuous mode
CANopen: (pre-)operational mode
SSI: no clock
PB/DN: no telegram traffic
RS 422: request mode
CANopen: stopped mode
Correction measures when there are error messages/pre-failure messages; see Troubleshooting in the
Appendix.
Function keys
Information field 2
Status indicators