Chapter
9
Operating Instructions
DME4000
124
© SICK AG • Germany • Subject to change without notice
8014584/ZN33/2017-07
Appendix
9.7
Hiperface
9.7.1
Type-Specific Setting
Typ ID
Period length (mm)
Free EERPOM (bytes)
Code 0 …3
90h
1
1792
55h
91h
2
1792
55h
92h
4
1792
55h
93h
8
1792
55h
94h
16
1792
55h
9.7.2
Overview of the support commands
Commandbyte
Function
Code 0
1)
Comments
42h
Read position
43h
Set position
•
44h
Read analog value
Channel number 48h
Temperature (
°
C)
46h
Read counter
47h
Increase counter
49h
Delete counter
•
4Ah
Read data
4Bh
Save data
4Ch
Determine the status of a data field
4Dh
Create data field
4Eh
Determine available memory
4Fh
Change access code
50h
Read transmitter status
Transmitter type = 22h
52h
Read type plate
53h
Reset transmitter
55h
Assign transmitter address
•
56h
Read serial number and program version
57h
Configure serial interface
•
1)
The correspondingly identified commands contain the parameter “Code 0”.
Code 0 is a byte, which is inserted for additional protection of important system parameters against unintentional overwriting in
the log. “Code 0” = 55h ex-works.