Betriebsanleitung
Kapitel
9
DME4000
8014584/ZN33/2017-07
© SICK AG • Deutschland • Irrtümer und Änderungen vorbehalten
55
Anhang
Parameter
ID Parameter
Current Value
Kapitel 3 Menü
1
Position Value
7295 counts
2
COS/Delta
0 counts
Anhang 0
3
Position State
Register
0 counts
See DeviceNet
Specification
4
Position Low
Limit
0 counts
See DeviceNet
Specification
5
Position High
Limit
0 counts
See DeviceNet
Specification
6
Offset Value
0 counts
3.6
7
Resolution
100
µ
m
3.5
8
Serial Mode
Baudrate
19200
3.2.1
9
Serial Mode Data 8n1
3.2.2
10
Plausibility
Off
3.7
11
MF1 ActiveState High
3.3.1
12
MF1 Function
Distance
3.3.2
13
MF2 ActiveState High
3.4.1
14
MF2 Function
Service
3.4.2
15
Service MF1
1101110
3.3.4
16
Service MF2
1101110
3.4.4
17
MF1 Temperature
UpperLimit
70
°
C
3.3.4.3
18
MF1 Temperature
LowerLimit
0
°
C
3.3.4.4
19
MF2 Temperature
UpperLimit
70
°
C
3.4.4.3
20
MF2 Temperature
LowerLimit
0
°
C
3.4.4.4
21
MF1 Distance
UpperLimit
2000 mm
3.3.3.1
22
MF1 Distance
LowerLimit
1990 mm
3.3.3.2
23
MF2 Distance
UpperLimit
2000 mm
3.4.3.1
24
MF2 Distance
LowerLimit
1990 mm
3.4.3.2
Parametrierung von MF1 und MF2
Gerätevarianten DME4000-xx5 sind nur mit einem 5-poligen DeviceNet-Stecker ausgerüstet. Die Multi-
funktionsein- und -ausgänge MF1 und MF2 sind hardwaremäßig nicht verfügbar.
Die Parametrierung von MF1 und MF2 ist trotzdem möglich und das Ergebnis kann im Diagnosebyte
(siehe Kapitel 9.6.3 „Datenaustausch“) über den Bus abgefragt werden.
Eine Parametrierung als Eingang ist nicht möglich. Die Funktionen Sleepmode und Preset sind über den
„Class Instance Editor“ möglich.
ACHTUNG