Chapter
3
Operating Instructions
DME4000
80
© SICK AG • Germany • Subject to change without notice
8014584/ZN33/2017-07
Menu Structure
Active
Not active
Level
On (default)
Pre-failure message
attenuation
Not soiled
Off
–
UpperTemp
On (default)
Excess temperature monitoring
Sensor temperature
> upper temperature limit set
Sensor temperature < upper
temperature limit set
Off
–
LowerTemp
On (default)
Subnormal temperature monitoring
Sensor temperature
< lower temperature limit set
Sensor temperature > upper
temperature limit set
Off
–
Plausib(ility)
On
(default)
Faulty measured valued, measured
value output “0”
Cause:
–Light beam interruption
–Vehicle speed
>
10 m/s
Measurement value OK
Off
–
Ready
On (default)
Initialization,
hardware defect,
measurement error,
laser switched off
Ready-to-operate,
measured value OK
Off
–
Bus Status
On
Bus error
SSI: no clock signal
PB/DN: no telegram traffic
CANopen: stopped mode
Data transmission OK
SSI: clock signal
PB/DN: telegram traffic
CANopen: (pre-)operational
mode
Off (default)
–
Speed
The “Speed” function makes output via both switching outputs MF1 and MF 2 possible when the pa-
rameterized speed limit is exceeded.
The switching hysteresis is fixed
±
0,1 m/s.
Active
Not active
Limit
On (default)
Range: 0,1 … 9,9 m/s
Range: 0 m/s
Off
–
Sign
On (default)
Parameterized speed limit is exceeded
and movement direction “+”.
Measured value becomes bigger;
Movement direction “-“: Measured
value becomes smaller;
Movement direction “+/-“: Measured
value in both directions
Parameterized speed limit is
not exceeded.
Off
–
Resolution
The resolution setting affects all interfaces.
Possible settings: 50 ... 5000
µ
m, default 100
µ
m