- Teach-in tolerance: Here you can set in three stages how precisely the taught-in
edge must be detected in terms of edge width and contrast difference. In the
coarse setting, edges that are less similar to the taught edge than in the sensitive
setting, for example, are also detected.
- Automated drift control: If active, the taught-in edge is readjusted over time in the
event of contamination.
- Device edge search mode: The use of search fields can be activated here.
- Search field width in micrometer: During teach-in, a search field is placed around
the edge position. The width of the search field can be set here beforehand. In the
following, only edges within the respective search fields are accepted.
After clicking “Advanced teach-in," a separate dialog window opens. The current
edge image can be frozen with “Teach-in snapshot.” Up to 8 edges can now be
defined for teach-in. The edges selected in each case are highlighted in green. The
selection of the edges here corresponds to the reading direction of the sensor and
the respective edge search direction per edge (see Process setup).
OPERATION
7
O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Extended Field of View
23
8026955/2022-02-16
| SICK
Subject to change without notice