5.2
Note on the swivel connector
NOTICE
Damage to the connector unit from over-tightening!
The connector unit on the device has two opposite end positions.
■
Do not rotate the connector unit from either of the two end positions by more than
180°.
5.3
Pin assignment of the connections
AS30
1 - BN
L+
2 - WH
Qa
3 - BU
M
4 - BK
C/Q
5 - GY
MF
1
2
4
3
5
Legend
L+ = Supply voltage
Qa = Analog output (information can be selected via edge 1, edge 2 or width/center
line)
M = Ground
C/Q = Communication and switching output
MF = External input, external teach-in, QL1 output, QL2 output, background teach-in,
input for changing the reading and searching direction
NOTICE
Crosstalk can occur on the analog output in IO-Link operation. Simultaneous operation
is not recommended.
5.4
Connecting the supply voltage
NOTICE
Risk of damage to the device!
The device can become damaged if it is connected to a voltage supply that is already
switched on.
•
Only connect the device when the supply cable is de-energized.
The device must be connected to a power supply unit with the following properties:
•
Supply voltage DC 18 V –30 V (SELV/PELV as per currently valid standards)
•
Electricity source with at least 3.1 W power
To ensure protection against short-circuits/overload in the customer’s supply cables,
the wire cross-sections used must be appropriately selected and protected.
ELECTRICAL INSTALLATION
5
O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Extended Field of View
15
8026955/2022-02-16
| SICK
Subject to change without notice