5.5
Wiring the interfaces
5.5.1
Wiring the digital inputs
Voltage level at the input starts the corresponding function of the device.
Electrical values
High: 12 V ≤ U ≤ U
V
Low: 0 V ≤ U ≤ 9 V
5.5.2
Wiring the digital outputs
In each case, the digital outputs are short-circuit protected and overcurrent protected.
Push/pull switching behavior
Electrical values
The sum current (100 mA) for all digital outputs is identical.
Push/pull
High: VS − 3 V
Low: ≤ 3 V
In the case of a push/pull sensor with PNP behavior, the signal must be inverted in
the control system in order to obtain the same result as a sensor with NPN switching
behavior.
Multi
Edge
PWR
Q
PWR
Q
PWR
Q
Output 1: Edge 1
Output 2: Edge 2
Output 3: 0
Output 1: Edge 1
Output 2: Edge 2
Output 3: Edge 3
Output 1: 0
Output 2: 0
Output 3: 0
Q
Push-
pull
(
≤
100 mA
)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
5
ELECTRICAL INSTALLATION
16
O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Extended Field of View
8026955/2022-02-16
| SICK