![SICK 1086947 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314067.webp)
GETTING STARTED…
4
67
8024172/V3-0/2021-01
Subject to change without prior notice.
Operating instructions | LABEL CHECKER P6XX
Match scenario example:
If you experience a situation similar with the unfavorable image (where the object is found
on a different location), you must increase the minimum match value or adjust the
settings of Object locator.
Recommended values are around 80%.
You must adjust the match settings conservatively, in order to control the step-by-
step adjustment.
8.
When all adjusted settings are finalized, click the
button to
confirm.
9.
Then, verify on the UI window if the shape is correctly highlighted.