5
LBC SOFTWARE
212
8024172/V3-0/2021-01|SICK
Oper at i ng i ns t r uc t i ons | LABEL CHECKER P6XX
Subject to change without prior notice.
3.
Delete these two files and leave only the bootinit.json file in the public folder,
then select the OK button to verify deletion.
Figure 142 Deleted files
4.
Copy your backup into the public folder without the bootinit.json file from the
backup. Backup files must be moved by “drag & drop” to the public subfolder of
the camera, and not directly into it.
Figure 143 Backup into public folder
The bootinit.json file keeps the information of the FW and SW version, including
the camera type (e.g. LBC621/LBC632), and is used when the configuration is
created. When these information differs, the camera automatically performs
“reset to factory defaults” and deletes all configuration. Thus, the bootinit.json
file must be replaced with the latest file from the target camera.