![SICK 1086947 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314063.webp)
GETTING STARTED…
4
63
8024172/V3-0/2021-01
Subject to change without prior notice.
Operating instructions | LABEL CHECKER P6XX
Contrast low
For this sample, try to avoid detecting the noise around the well-defined object.
Set the contrast low, contrast hysteresis, and minimum segment length to
highlight only the contours, and if possible, no noise present.
High contrast
The high contrast sample
shows incomplete
highlighted edges.
Optimal
The image shows
favorable filtered pixels.
Low contrast
Adjusting to a lower value
will make the contrast
adjustment very sensitive,
that it will be able to
detect minor pixels.
Figure 35 Contrast low