![SICK 1086947 Скачать руководство пользователя страница 183](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314183.webp)
GETTING STARTED…
4
183
8024172/V3-0/2021-01
Subject to change without prior notice.
Operating instructions | LABEL CHECKER P6XX
Table 8 Other strings
Other
Region - Name and Id of inspection/region defined by the operating
entity in the current job.
Format:
regionName.Id. (Cannot be set).
List of Items to be sent - One inspection/region contained in output
string (cannot be set).
# - table line number (Cannot be set).
Available
Results
Inspection/Regions which are defined in the current job. Such as;
object locator, OCR/OCV, 1D/2D Code,
This list corresponds to the regions added in a current job for:
Object locator page
OCR/OCV page
1D code page
2D code page
Measurement 2D page
Pixel counter page
Pattern verifier page
# - Table line number (not important)
Region – Name and Id of inspection/region defined by a user in a
current job. Format: regionName.Id.
Control Buttons
Add Result
Add selected inspection/region to an output string.
Remove Result
Remove selected region from the output string.
Modify Result
Change parameters of selected part of the output string having
regard the following parameters: Read Text, Region type, Region Id,
Result, Expected text, Length Type, Length, Fill Symbol, Padding, and
No Read strings.
Overall results parameter – complete results of all defined
inspections.