Operating instructions | LABEL CHECKER P6XX
Inverted
Invert output logic
When the Inverted parameter is set to ON, then Logical “true” means 0 V, and logical
“false” means 24 V.
Enabled
Output activated
Inverted activation type
New result
–
OK/NOK signal is activated when new result is computed.
Time-Controlled – Output activated. Start offset must be greater than the
camera execution time.
Figure 93
Time diagram
The time diagram demonstrates two trigger signals. Where first part shows OK signal with
Activation type – “New results”, and second part NOK with Time-controlled activation type.
There is a possibility to set the delay of the trigger signal or the delay of the output signal
in millimeters.
When the encoder delay is selected, the D03 is automatically deactivated, thus there will
be only two outputs left to be utilized.