![SICK 1086947 Скачать руководство пользователя страница 143](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314143.webp)
GETTING STARTED…
4
143
8024172/V3-0/2021-01
Subject to change without prior notice.
Operating instructions | LABEL CHECKER P6XX
Setting the output delays in millimeters
Figure 95 DO delays in millimeters
When set in millimeters, the encoder resolution must be precisely set.
4.13.4
Light settings
Used to select which illumination is used.
Internal light – Driven by the camera itself, but can be disabled when not in use.
External light via connector External light – Enabled only for LBC632 and LBC631.
External light via DI4 - Enabled for Label Checker 621/63x/642/65x
The settings must be adjusted when adding an external light.