Parameter
Factory setting
Q1 teach-in:
Q1, Q1 not
-
Manual Q1 teach-in:
-1,000.0 mm ... +1,000.0 mm
+400 mm
Q1 active status:
High, Low
High
Q1 hysteresis:
0000.0 mm ... +0100.0 mm
+1.0 mm
Delay mode:
Off
Switch-on delay
Switch-off delay
Switch-on/switch-off delay
1 shot
✓
-
-
-
-
Time for delay mode:
0000 ms ... 9,999 ms
100 ms
8.4.1.3
Window
Window mode: An upper and a lower switching threshold are set for the digital output. If
the measured value is between the two switching thresholds (within the window), a
switching signal is output.
Minimum
1
Maximum
4
2
1
0
3
Figure 16: Normally open switching window (High Active, PNP)
1
Minimum
2
Switching point near
3
Switching point far
4
Maximum
Minimum
1
Maximum
4
2
1
0
3
Figure 17: Normally closed switching window (Low Active, PNP)
1
Minimum
2
Switching point near
3
Switching point far
4
Maximum
>
I/O interface
>
>
Q1 output
>
>
Window
>
8
OPERATION VIA DISPLAY
42
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/18JN/2020-07-01 | SICK
Subject to change without notice