Real distance
Measured value without averaging (Avg: OFF)
Output signal
Time t
1
Measured value with median (Avg: 63)
2
4
Measured value with averaging (Avg: 64)
3
4
3
2
1
Figure 13: Measured value filter
1
Output signal
2
True distance
3
Measured value with median (avg: 63)
4
Measured value with averaging (avg: 64)
5
Measured value without averaging (avg: OFF)
6
Time t
>
Measurement
>
>
Default settings
>
>
Measured value filter
>
Parameter
Factory setting
Do not use a filter
x
Averaging filter:
4, 8, 16, 32, 64, 512
-
Median filter:
3, 7, 15, 31, 63, 511
-
8.3.2.3
Bit filter
The bit filter for digital outputs determines how often an identical output state has to
recur consecutively before the signal at the digital output changes accordingly.
8
OPERATION VIA DISPLAY
36
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/18JN/2020-07-01 | SICK
Subject to change without notice