Display
Status
Meaning
Output displays Q
1
Ö
Ö
Simultaneous
Teach-in operation is carried out
Ö
Ö
5 seconds in alter‐
nation
Teach-in operation has failed
Ö
Ö
Permanently in
alternation
There is a fault
o
Does not light up
Ö
Flashing
O
Permanently on
7.2.2
Operating buttons
Pushbutton
Function
Description
Open menu/
confirm
Opens the menu, confirms entries, or switches to the next menu
level of a selected element.
Moves the cursor to the right when entering numbers.
Cancel
Switches to the previous menu level.
Moves the cursor to the left when entering numbers.
Navigate
Switches between multiple screens on one menu level.
Increases the value when entering numbers.
Navigate
Switches between multiple screens on one menu level.
Reduces the value when entering numbers.
Activating and deactivating the operating button lock
To prevent accidental operation, lock and unlock the operating buttons using a short‐
cut:
b
Press and hold the
and
pushbuttons simultaneously for > 3 seconds.
✓
When the pushbutton lock is activated, the padlock symbol appears in the dis‐
play. When the pushbutton lock is deactivated, the padlock symbol is not dis‐
played.
NOTE
The operating button lock can also be activated and deactivated via SOPAS ET or IO-
Link.
7.3
Operating concept
The device can be operated using the following methods:
•
Display and operating buttons on the device,
.
•
SOPAS ET user interface (computer),
see "Operation via SOPAS ET", page 59
.
•
IO-Link,
see "Operation via IO-Link", page 58
.
OPERATION
7
8019642/18JN/2020-07-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD1000
23
Subject to change without notice