background image

USER MANUAL

 

 

3

 

z

 

Check that the available voltage is not higher than the one stated on the rear 

panel of the unit. 

z

 

The power cord should always be in perfect condition: switch the unit 

immediately off when the power cord is squashed or damaged. 

z

 

Never let the power-cord come into contact with other cables. 

z

 

This fixture must be earthed to in order comply with safety regulations. 

z

 

Don’t connect the unit to any dimmer pack. 

z

 

Always use an appropriate and certified safety cable when installing the unit. 

z

 

In order to prevent electric shock, do not open the cover, Apart from the lamp 

and mains fuse there are no user serviceable parts inside. 

z

 

Never

 repair a fuse or bypass the fuse holder. 

Always

 replace a damaged fuse 

with a fuse of the same type and electrical specifications! 

z

 

In the event of serious operating problems. stop using the fixture and contact 

your dealer immediately 

z

 

The housing and the lenses must be replaced if they are visibly damaged. 

z

 

Please use the original packing when the device is to be transported. 

z

 

Due to safety reasons it is prohibited to make unauthorized modifications to the 

unit. 

 

4. LASER SAFETY INSTRUCTIONS: 

z

 

According to the EN 60825-1

1994 + A2

2002 regulations, this laser fall under 

the classification 3B.Direct eye exposure can be dangerous. 

 

 

 

 

 

z

 

This is so-called show laser, emitting radiation with a wavelength spectrum 

between 400 and 700nm and producing lighting effects for shows. 

z

 

Due to the instruction of this laser, the beam is moved so fast, that it can only hit 

the eye very short. This is why the use of this laser for a laser-light show can be 

regarded as save. 

z

 

Never direct the laser beam to people or animals and never leave this device 

running unattended. 

 

Important: Never look directly into the light source! Don’t use the effect 

in the presence of persons suffering from epilepsy. 

Содержание Galactic G-30

Страница 1: ...t laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this ma...

Страница 2: ...rol z DMX addressing with LED display z Laser Safety key switch z Complies to EN IEC 60825 1 for Laser Safety 2 BEFORE USE z Before you start using this unit please check if there s no transportation...

Страница 3: ...way from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls z Don t cover any ventilation openings as this may result in overheating z Prevent use in...

Страница 4: ...problems stop using the fixture and contact your dealer immediately z The housing and the lenses must be replaced if they are visibly damaged z Please use the original packing when the device is to b...

Страница 5: ...llations and unskilled operation 5 OVERHEAD RIGGING z Important The installation must be carried out by qualified service personal only Improper installation can result in serious injuries and or dama...

Страница 6: ...g and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure that safety is stil...

Страница 7: ...DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you ne...

Страница 8: ...ransmission on the data link 6 DESCRIPTION 6 1 Back panel of the fixture 1 POWER Switch Switch on and off the power 2 MAINS INPUT with IEC socket and integrated fuse holder connect the supplied mains...

Страница 9: ...the space color laser with the next unit in the DMX chain 12 DMX INPUT 3pin male XLR connector used to connect universal DMX cables This input receives instructions from a DMX controller 6 2 Front pan...

Страница 10: ...re and contact your dealer immediately z Important Never look directly into the laser beam Don t use the effect in the presence of persons suffering from epilepsy You can operate the unit in 5 Modes 7...

Страница 11: ...am The laser is operating this mode until next setting 7 3 SLAVE MODE z Press FUNC button till to the SLA letter is shown on LED DISPLAY z Press ENTER to select this SLA mode When SLA mode is selected...

Страница 12: ...ler as function list below The laser is operating this mode until next setting z STAND BY button Used to set the connected unit in blackout mode The LED is on when the unit is set to blackout z MODE F...

Страница 13: ...CONTROL MODE and confirm the DMX address CAUTION In case of DMX cable disconnecting or no DMX signal is detected the DMX address on LED DISPLAY keeps flashing Please check the DMX cable connection Imp...

Страница 14: ...127 Pattern Group 2 TUNNEL 128 191 Pattern Group 3 CURVE 192 255 Pattern Group 4 OTHERS 3 000 255 8 Patterns in each group in Channel 2 4 000 134 Rotation Position 135 255 Rotating Speed 5 0 128 Size...

Страница 15: ...USER MANUAL 14 8 2 PATTERN LIST IN CHANNEL 3 DMX Group 1 Group 2 Group 3 Group 4 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255...

Страница 16: ...USER MANUAL 15 9 OUTPUT LASER ADJUSTMENT 9 1 To adjust the output laser beam position and direction 9 2 X Y AXIS ZOOMING ADJUSTMENT...

Страница 17: ...replaced immediately when even a small problem is detected z In order to protect the device from overheat the cooling fans if any and ventilation openings should be cleaned monthly z The interior of...

Страница 18: ...USER MANUAL 17 11 CIRCUIT DIAGRAM 3 2 1 3 2 1 B 5 0 K E N L...

Страница 19: ...ser Diode Blanking 1 1000Hz z Sound Control Internal microphone z DMX connections 3pin XLR male female z DMX channels 8 channels z Laser Power 30mW Green CW laser 532nm z Laser radiation class 3B z La...

Отзывы: