34
< NOTE >
Inner air element must not be reused even if it is cleaned.
Replace the inner element when replacing the outer
element.
Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
Replace the elements earlier if using in an excessively
dusty location.
Do not add oil as this generator uses a dry element.
Clear foreign material by pinching the vacuator valve
once a week in normal operating conditions or daily if
operating in a location that is excessively dirty or dusty.
Wipe away any dirt or moisture that has adhered to the
parts.
Never touch the elements for any reason except
cleaning.
Element part nos.
Outer Element
59700-26112
Kubota Part No.
Inner Element
55231-26151
Cleaning the air filter element (outer element)
If dry dust is adhering:
Blow compressed air from inside the element.
If carbon or oil is adhering:
Replace with new parts.
(4) Draining Water from the Water Separator
Check
Daily
Clean
Every 200 hours
Drain water when the float (red) inside the cup floats to
the water draining position.
Close the fuel valve.
Loosen the lower valve.
After water has been drained, tighten the lower valve.
If foreign material is adhering to the gauze filter in the
cup, remove the cup, float and gauze filter, and clean
by blowing compressed air from the inside of the
gauze filter.
Reassemble the gauze filter, cup and float to their original location.
< NOTE >
When attaching the cup, check that there is no foreign material adhering to the O-ring.
After attaching, open the fuel valve, and be sure to always start the engine and check that there is
no fuel leakage.
1
Clip
Air Cleaner Cap
Air Cleaner
Outer Element
Inner Element
Vacuator
Valve
Air Cleaner Cap
2
3
4
5
Close
Lever
Cup
Gauze Filter
Water Drain Level
Faucet
Float (Red)
Open
Содержание DGM60MK
Страница 2: ......
Страница 46: ...43 13 Generator Circuit Diagram...
Страница 47: ...44 14 Engine Electrical Circuit Diagram...
Страница 48: ...2011...