40
Allow water to accumulate and check that the spill containment has no internal leakage.
Open the drain valve lever to drain the water.
After the procedures have been completed, close the drain valve lever and apply the
sealant coating to the plug (R1/2) or wrap it by seal tape and tighten it.
< Note >
If the fluid drained when cleaning the spill containment contains oil or grease, dispose of it
according to the related laws and regulations.
If the spill containment has a leak, contact the authorized distributor where the generator was
purchased.
6
Lifting Hook
Wiring Connector
Spill Containment
Fixing Bolts (M8)
-Right Side: 4 pieces
-Left Side: 3 pieces
Wiring Connector
Side Door
5